Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle.
The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin.
The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro.
The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ.
Vascular Solutions, Inc.
4000
In Commercial Distribution
- M20640000 ()
- M20640001 ()
- Collagen haemostatic agent, non-antimicrobial
PCP25
PREMIER BIOTECH, INC
PBCard-01-PCP
In Commercial Distribution
- B313PBCARD01PCP1 ()
- B313PBCARD01PCP0 ()
PBCard-01-PCP
- Multiple drugs of abuse IVD, kit, rapid ICT, clinical
Single Dip Cassette Drug Test, PCP
EXPRESS DIAGNOSTICS INT'L, INC.
30180C
Not in Commercial Distribution
- B29830180C0 ()
30180C
- Phencyclidine (PCP) IVD, kit, rapid ICT, clinical
Single Dip Drug Test, PCP
EXPRESS DIAGNOSTICS INT'L, INC.
30180
Not in Commercial Distribution
- B298301800 ()
30180
- Phencyclidine (PCP) IVD, kit, rapid ICT, clinical
Integra® Wound Matrix (Thin)
Integra Lifesciences Corporation
58101T
In Commercial Distribution
- M26958101T1 ()
- 10381780032434 ()
- Length: 10 Inch
- Width: 8 Inch
- Width: 20 Centimeter
- Length: 25 Centimeter
58101T
- Collagen wound matrix dressing
Integra® Wound Matrix (Thin)
Integra Lifesciences Corporation
54101T
In Commercial Distribution
- M26954101T1 ()
- 10381780032427 ()
- Width: 10 Centimeter
- Length: 10 Inch
- Width: 4 Inch
- Length: 25 Centimeter
54101T
- Collagen wound matrix dressing
Integra Wound Matrix and Integra Wound Matrix (Thin) are collagen-glycosaminoglycan wound dressings that maintain and support a healing environment for wound management. Integra Wound Matrix (Thin) has 50% less collagen compared to each of the corresponding sq cm sizes of Integra Wound Matrix.
Integra Lifesciences Corporation
54051T
In Commercial Distribution
- M26954051T1 ()
- 10381780032410 ()
- Width: 10 Centimeter
- Length: 12.5 Centimeter
- Length: 5 Inch
- Width: 4 Inch
54051T
- Collagen wound matrix dressing
Integra® MATRIX WOUND DRESSING 4 in X 5 in (10 cm X 12.5 cm)
Integra Lifesciences Corporation
54051
In Commercial Distribution
- M269540511 ()
- 10381780032298 ()
- Length: 12.5 Centimeter
- Length: 5 Inch
- Width: 10 Centimeter
- Width: 4 Inch
54051
- Collagen wound matrix dressing
INTEGRA Bilayer Matrix Wound Dressing is an advanced woundcare device comprised of a porous matrix of cross-linked bovine tendon collagen and glycosaminoglycan and a semi-permeable polysiloxane (silicone) layer. The semi-permeable silicone membrane controls water vapor loss, provides a flexible adherent covering for the wound surface and adds increased tear strength to the device. The collagen-glycosaminoglycan biodegradable matrix provides a scaffold for cellular invasion and capillary growth.
Integra Lifesciences Corporation
BMW410
In Commercial Distribution
- M269BMW4101 ()
- 10381780032267 ()
- 00381780032260 ()
- Length: 10 Inch
- Length: 25 Centimeter
- Width: 10 Centimeter
- Width: 4 Inch
BMW410
- Collagen wound matrix dressing
INTEGRA® BILAYER MATRIX WOUND DRESSING 8 in*10 in (20 cm*25 cm)
Integra Lifesciences Corporation
BMW8101
In Commercial Distribution
- M269BMW81011 ()
- 10381780032236 ()
- Length: 25 Centimeter
- Width: 20 Centimeter
- Width: 8 Inch
- Length: 10 Inch
BMW8101
- Collagen wound matrix dressing