SEARCH RESULTS FOR: ("cryptocurrency meaning in bengali馃挷itenthusiasts.com馃挷Cryptocurrency")(310 results)
Valve in Cartridge, 9mm
Gyrus Acmi, Llc
HUS-V9
In Commercial Distribution
- 00896506002200 ()
- Outer Diameter: 9 Millimeter
- Endobronchial valve
Valve in Cartridge, 7mm
Gyrus Acmi, Llc
HUS-V7
In Commercial Distribution
- 00896506002101 ()
- Outer Diameter: 7 Millimeter
- Endobronchial valve
Valve in Cartridge, 6mm
Gyrus Acmi, Llc
HUS-V6
In Commercial Distribution
- 00896506002095 ()
- Outer Diameter: 6 Millimeter
- Endobronchial valve
Valve in Cartridge , 5mm
Gyrus Acmi, Llc
HUS-V5
In Commercial Distribution
- 00896506002088 ()
- Outer Diameter: 5 Millimeter
- Endobronchial valve
CliniMACS® Tubing Set (TS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73105
In Commercial Distribution
- 04049934004834 ()
161-01
- Magnetic cell separation system tubing set
CliniMACS® CD34 Reagent is a dark amber, non-viscous, colloidal solution containing an antibody conjugate in buffer. The conjugate consists of a murine IgG1 monoclonal antibody directed against the Class II epitope of the human CD34 antigen, which is chemically conjugated to dextran beads having an iron oxide/hydroxide core used in conjuction with the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
70103
In Commercial Distribution
- 04049934004827 ()
171-01
- Magnetic cell separation system reagent
The CliniMACS® plus Instrument is a software-controlled instrument that processes the HPC, Apheresis as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
75101
In Commercial Distribution
- 04049934004636 ()
151-01
- Magnetic cell separation system processing unit
CliniMACS® Tubing Set (LS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73205
In Commercial Distribution
- 04049934004841 ()
162-01
- Magnetic cell separation system tubing set
CliniMACS® PBS/EDTA Buffer is a single-use, sterile, isotonic buffer solution used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
70026
In Commercial Distribution
- 04049934004674 ()
- 04049934001666 ()
700-25
- Magnetic cell separation system buffered saline solution
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures a minimum of 50 cm2 in area.
Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
N/A
In Commercial Distribution
- W41020AU201S1969 ()
- Area/Surface Area: 50 Square centimeter
- Cultured skin autograft/xenograft