SEARCH RESULTS FOR: !➧주식DB구합니다◀✅텔레그램thinkDB(525 results)
CliniMACS® CD34 Reagent is a dark amber, non-viscous, colloidal solution containing an antibody conjugate in buffer. The conjugate consists of a murine IgG1 monoclonal antibody directed against the Class II epitope of the human CD34 antigen, which is chemically conjugated to dextran beads having an iron oxide/hydroxide core used in conjuction with the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
70103
In Commercial Distribution
- 04049934004827 ()
171-01
- Magnetic cell separation system reagent
CliniMACS® PBS/EDTA Buffer is a single-use, sterile, isotonic buffer solution used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
70026
In Commercial Distribution
- 04049934004674 ()
- 04049934001666 ()
700-25
- Magnetic cell separation system buffered saline solution
The CliniMACS® plus Instrument is a software-controlled instrument that processes the HPC, Apheresis as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
75101
In Commercial Distribution
- 04049934004636 ()
151-01
- Magnetic cell separation system processing unit
TOOL NU1022 ENSEMBLE HDE
MEDTRONIC, INC.
NU1022
Not in Commercial Distribution
- 00613994666000 ()
- Outer Balloon Size 22 MM
- Pulmonary transcatheter heart valve bioprosthesis
TOOL NU1020 ENSEMBLE HDE
MEDTRONIC, INC.
NU1020
Not in Commercial Distribution
- 00613994665997 ()
- Outer Balloon Size 20 MM
- Pulmonary transcatheter heart valve bioprosthesis
TOOL NU1018 ENSEMBLE HDE
MEDTRONIC, INC.
NU1018
Not in Commercial Distribution
- 00613994665980 ()
- Outer Balloon Size 18 MM
- Pulmonary transcatheter heart valve bioprosthesis
VALVE PB1018 MELODY HDE
MEDTRONIC, INC.
PB1018
Not in Commercial Distribution
- 00613994663962 ()
- Valve Size 18 MM
- Pulmonary transcatheter heart valve bioprosthesis
INS 37800 ENTERRA II NEUROSTIMULATOR
MEDTRONIC, INC.
37800
In Commercial Distribution
- 00643169360686 ()
- Gastric electrical stimulation system
CNDT 200SH22 CONTEGRA GBR1 HDE TEMP IND
MEDTRONIC, INC.
200SH22
Not in Commercial Distribution
- 00643169357167 ()
- Valve Size 22 MM
- Pulmonary open-surgery heart valve bioprosthesis
CNDT 200SH20 CONTEGRA GBR1 HDE TEMP IND
MEDTRONIC, INC.
200SH20
Not in Commercial Distribution
- 00643169357150 ()
- Valve Size 20 MM
- Pulmonary open-surgery heart valve bioprosthesis