microTargeting(TM) Electrode, non-sterile, single, D.ZAP(Z) T=30, for use with Frame and STar or MT Drive
FHC, INC.
34625Z-00249
In Commercial Distribution

  • 10873263002497 ()
  • 00873263002490 ()

  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
34625Z

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, single, DZAP(L) T=30, for use with Frame and STar or MT Drive
FHC, INC.
34625L-00248
In Commercial Distribution

  • 10873263002480 ()
  • 00873263002483 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 271.4 Millimeter
  • Impedance: Megaohms
34625L

  • Depth electrode
microTargeting(TM) Electrode, non sterile, 6x, Array, D.ZAP(Z), T=30 for use with frame, STar or MT Drive
FHC, INC.
22635Z-00241
In Commercial Distribution

  • 10873263002411 ()
  • 00873263002414 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
22635Z

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, 6x, array, D.ZAP(L), T=30 for use with frame, STar or MT Drive
FHC, INC.
22635L-00240
In Commercial Distribution

  • 10873263002404 ()
  • 00873263002407 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
22635L

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, Array, 1 Meg, T=30 for use with frame and STar or mT drive
FHC, INC.
22630R-00239
In Commercial Distribution

  • 10873263002398 ()
  • 00873263002391 ()

  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 261.5 Millimeter
  • Impedance: Megaohms
22630R

  • Depth electrode
microTargeting Electrode 6x, non-sterile, Array, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1003-00136
Not in Commercial Distribution

  • 10873263001360 ()
  • 00873263001363 ()

  • Length: 276.5 Millimeter
  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
FC1003

  • Depth electrode
microTargeting Electrode 6x, non-sterile, Single, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1002-00135
Not in Commercial Distribution

  • 10873263001353 ()
  • 00873263001356 ()

  • Length: 271.4 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
FC1002

  • Depth electrode
Rod, MIS, Lordotic 5.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
M-01-030
In Commercial Distribution

  • 00814008029594 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 8.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-850-030
In Commercial Distribution

  • 00814008029426 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 7.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-750-030
In Commercial Distribution

  • 00814008029341 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
< 1 ... 3 4 5 6 7 8 >