R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25100ER
In Commercial Distribution

  • 04540778175334 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 2.5 mm
BD-Q25100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20100ER
In Commercial Distribution

  • 04540778175310 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 2.0 mm
BD-Q20100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50080ER
In Commercial Distribution

  • 04540778175273 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 5.0 mm
BD-Q50080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30080ER
In Commercial Distribution

  • 04540778175235 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 3.0 mm
BD-Q30080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20080ER
In Commercial Distribution

  • 04540778175198 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 2.0 mm
BD-Q20080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60060ER
In Commercial Distribution

  • 04540778175174 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 60 mm
  • Balloon Diameter; 6.0 mm
BD-Q60060ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50060ER
In Commercial Distribution

  • 04540778175150 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 60 mm
  • Balloon Diameter; 5.0 mm
BD-Q50060ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40060ER
In Commercial Distribution

  • 04540778175136 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 60 mm
  • Balloon Diameter; 4.0 mm
BD-Q40060ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30060ER
In Commercial Distribution

  • 04540778175112 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 60 mm
  • Balloon Diameter; 3.0 mm
BD-Q30060ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25060ER
In Commercial Distribution

  • 04540778175099 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 60 mm
  • Balloon Diameter; 2.5 mm
BD-Q25060ER

  • Peripheral angioplasty balloon catheter, basic