Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI1005
In Commercial Distribution
- 00860011603610 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI0704
In Commercial Distribution
- 00860011603603 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450296097
In Commercial Distribution
- 10884450296094 ()
- 00884450296097 ()
- Length-17.5 cm
- Size-Long
- Gauge-11G
STR-1015L/A
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450296080
In Commercial Distribution
- 10884450296087 ()
- 00884450296080 ()
- Length-17.5 cm
- Gauge-11G
- Size-Long
STR-0510L/A
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450320679
In Commercial Distribution
- 00884450320679 ()
- Size-Long
- Gauge-10/11G
RF-0510L-01/B
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450320662
In Commercial Distribution
- 00884450320662 ()
- Gauge-10/11G
- Size-Short
RF-0510S-01/B
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450320655
In Commercial Distribution
- 00884450320655 ()
- Size-Long
- Gauge-10/11G
RF-1015L-01/B
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Merit Medical Systems, Inc.
00884450320648
In Commercial Distribution
- 00884450320648 ()
- Size-Short
- Gauge-10/11G
RF-1015S-01/B
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
RFTL
20G x 145mm
stimulation tip 10mm, grinding 15°
Pajunk GmbH Medizintechnologie
001165-30CM
Not in Commercial Distribution
- 14048223016791 ()
- 04048223016794 ()
001165-30CM
- Percutaneous radio-frequency ablation probe cannula, single-use
RFTL
20G x 98,6mm
stimulation tip 10mm, grinding 15°
Pajunk GmbH Medizintechnologie
001165-30D
Not in Commercial Distribution
- 14048223016784 ()
- 04048223016787 ()
001165-30D
- Percutaneous radio-frequency ablation probe cannula, single-use