SEARCH RESULTS FOR: (*EPP Heating Room*)(36193 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Microwave Tissue Ablation Applicator
ANGIODYNAMICS, INC.
700106002-US
In Commercial Distribution
- H787700106002US0 ()
- 15051684017855 ()
- Length: 19 Centimeter
- Microwave hyperthermia system applicator, intracorporeal
Microwave Tissue Ablation Applicator
ANGIODYNAMICS, INC.
700106001-US
In Commercial Distribution
- H787700106001US0 ()
- 15051684017848 ()
- Length: 14 Centimeter
- Microwave hyperthermia system applicator, intracorporeal
CliniMACS® Tubing Set (LS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73205
In Commercial Distribution
- 04049934004841 ()
162-01
- Magnetic cell separation system tubing set
CliniMACS® Tubing Set (TS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73105
In Commercial Distribution
- 04049934004834 ()
161-01
- Magnetic cell separation system tubing set
Legato® Probe monopolar, Ball Tip, straight
Joimax GmbH
JMPP27025*
In Commercial Distribution
- 04250337115243 ()
- 04250337115250 ()
JMPP27025*
- Radio-frequency ablation system
Inject Electrode,5cm,6mm tip,16G Curved
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
CUR-5616
In Commercial Distribution
- 00813250017779 ()
- 00813250017762 ()
- 16 ga Diameter
- 5 cm Length
- 6 mm Length
- Radio-frequency ablation system
Inject Electrode,15cm,10mm tip16G Curved
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
CUR-151016
In Commercial Distribution
- 00813250017731 ()
- 00813250017724 ()
- 16 ga Diameter
- 10 mm Length
- 15 cm Length
- Radio-frequency ablation system
Cannula, 10cm, 5mm tip, 22G Sharp Curved
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
RFK-C10522VZ
In Commercial Distribution
- 00813250017670 ()
- 00813250017663 ()
- 5 mm Length
- 10 cm Length
- 22 ga Diameter
- Radio-frequency ablation system
Palisade-20G, 4 TCD-10 and 6 CC101020
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
PALISADE-20
In Commercial Distribution
- 00813250017632 ()
- 20 ga Diameter
- Radio-frequency ablation system
BIPOLAR DISC KIT 2 CC152020 TCD-15
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
BDK-15
In Commercial Distribution
- 00813250017601 ()
- Radio-frequency ablation system