RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ3212UA2
In Commercial Distribution

  • 04540778170315 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 3.25 mm
DC-RZ3212UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ3012UA2
In Commercial Distribution

  • 04540778170292 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 3.0 mm
DC-RZ3012UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ2712UA2
In Commercial Distribution

  • 04540778170278 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 2.75 mm
DC-RZ2712UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ2512UA2
In Commercial Distribution

  • 04540778170254 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 2.5 mm
DC-RZ2512UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ2212UA2
In Commercial Distribution

  • 04540778170230 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 2.25 mm
DC-RZ2212UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ2012UA2
In Commercial Distribution

  • 04540778170216 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.6 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 2.0 mm
DC-RZ2012UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ5008UA2
In Commercial Distribution

  • 04540778170193 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 5.0 mm
DC-RZ5008UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ4508UA2
In Commercial Distribution

  • 04540778170179 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 4.5 mm
DC-RZ4508UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ4008UA2
In Commercial Distribution

  • 04540778170155 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 4.0 mm
DC-RZ4008UA2

  • Coronary angioplasty balloon catheter, basic
RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RZ3708UA2
In Commercial Distribution

  • 04540778170131 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 12 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 3.75 mm
DC-RZ3708UA2