SEARCH RESULTS FOR: (*One Satoshi(hkotc.cc)Z0ft*)(52232 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4020UA2
In Commercial Distribution
- 04540778168312 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 4.0 mm
DC-RY4020UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3720UA2
In Commercial Distribution
- 04540778168299 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.75 mm
DC-RY3720UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3520UA2
In Commercial Distribution
- 04540778168275 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.5 mm
DC-RY3520UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3220UA2
In Commercial Distribution
- 04540778168251 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.25 mm
DC-RY3220UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3020UA2
In Commercial Distribution
- 04540778168237 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.0 mm
DC-RY3020UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2720UA2
In Commercial Distribution
- 04540778168213 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.75 mm
DC-RY2720UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2520UA2
In Commercial Distribution
- 04540778168190 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.5 mm
DC-RY2520UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2220UA2
In Commercial Distribution
- 04540778168176 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.25 mm
DC-RY2220UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2020UA2
In Commercial Distribution
- 04540778168152 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.0 mm
DC-RY2020UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY1520UA1
In Commercial Distribution
- 04540778168138 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 20 mm
- Balloon Diameter; 1.5 mm
DC-RY1520UA1
- Coronary angioplasty balloon catheter, basic