RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY5015UA2
In Commercial Distribution
- 04540778168114 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 6 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 5.0 mm
DC-RY5015UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4515UA2
In Commercial Distribution
- 04540778168091 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 6 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 4.5 mm
DC-RY4515UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4015UA2
In Commercial Distribution
- 04540778168077 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 4.0 mm
DC-RY4015UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3715UA2
In Commercial Distribution
- 04540778168053 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 3.75 mm
DC-RY3715UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3515UA2
In Commercial Distribution
- 04540778168039 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 3.5 mm
DC-RY3515UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3215UA2
In Commercial Distribution
- 04540778168015 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 3.25 mm
DC-RY3215UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3015UA2
In Commercial Distribution
- 04540778167995 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 3.0 mm
DC-RY3015UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2715UA2
In Commercial Distribution
- 04540778167971 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 2.75 mm
DC-RY2715UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2515UA2
In Commercial Distribution
- 04540778167957 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 2.5 mm
DC-RY2515UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2215UA2
In Commercial Distribution
- 04540778167933 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 15 mm
- Balloon Diameter; 2.25 mm
DC-RY2215UA2
- Coronary angioplasty balloon catheter, basic