SEARCH RESULTS FOR: 俄罗斯出海推广花费🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(10520 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
12.5F X 24CM HEMO-FLOW12.5F X 24 DUAL LUMEN CATHETER SETDUAL LUME (CUFF 19CM FROM TIP)(CUFF 19CM F
Medical Components, Inc.
PL24
Not in Commercial Distribution
- 50884908037161 ()
- 00884908037166 ()
PL24
- Double-lumen haemodialysis catheter, implantable
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SHC02
In Commercial Distribution
- B066SHC023 ()
- B066SHC020 ()
SHC02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SFC02
In Commercial Distribution
- B066SFC023 ()
- B066SFC020 ()
SFC02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SFB02
In Commercial Distribution
- B066SFB023 ()
- B066SFB020 ()
SFB02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SDB02
In Commercial Distribution
- B066SDB023 ()
- B066SDB020 ()
SDB02
- Cardiopulmonary bypass system blood tubing set
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
NOVOSCI CORP.
301028-000
In Commercial Distribution
- B0663010280006 ()
- B0663010280000 ()
- B0663010280005 ()
- B0663010280004 ()
- B0663010280003 ()
301028-000
- Cardioplegia solution administration adaptor
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
NOVOSCI CORP.
301022-000
In Commercial Distribution
- B0663010220006 ()
- B0663010220000 ()
- B0663010220005 ()
- B0663010220004 ()
- B0663010220003 ()
301022-000
- Cardioplegia solution administration adaptor
No Description
ZIMMER ORTHOPAEDIC SURGICAL PRODUCTS, INC.
09024076YT1
In Commercial Distribution
- 00846795029198 ()
- Length: 24 Millimeter
- Width: 9 Millimeter
- 0.64/0.76mm Thick
- Surgical saw blade, oscillating, single-use
No Description
ZIMMER ORTHOPAEDIC SURGICAL PRODUCTS, INC.
09024076AT1
In Commercial Distribution
- 00846795028993 ()
- Length: 24 Millimeter
- Width: 9 Millimeter
- 0.64/0.76mm Thick
- Surgical saw blade, oscillating, single-use
Restorelle® Y Contour™ Polypropylene Mesh for sacrocolposuspension/sacrocolpopexy with Meridian® VPS™ Vaginal Positioning System
Coloplast A/S
52081
In Commercial Distribution
- 05708932553773 ()
- Length: 24 Centimeter
- Width: 3 Centimeter
52081
- Pelvic organ prolapse surgical mesh, synthetic polymer