SEARCH RESULTS FOR: !$최신효율적인주식DB문의처☑️!텔DBchance(1545482 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
No Description
SPIRAIR, INC.
FG-0032
In Commercial Distribution
- 00860011696315 ()
SPLN005
- Nasal cartilage support implant, bioabsorbable
- Nasal cartilage support implant introducer
No Description
SPIRAIR, INC.
FG-0032
In Commercial Distribution
- 00860011696308 ()
SPLN001
- Nasal cartilage support implant, bioabsorbable
- Nasal cartilage support implant introducer
Carpal Tunnel Release, (1) SurePass CTR Guide, (1) SurePass CTR Knife Blade
Dev4
CT-1000
In Commercial Distribution
- 00860011634812 ()
- Orthopaedic surgical procedure kit, non-medicated, single-use
Small Bone Extraction Tool
Dev4
TP-1000
In Commercial Distribution
- 00860011634805 ()
- Bone curette, single-use
The device is designed to be placed temporarily over a skin incision to assist with holding suture tension prior to final closure.
DRS Vascular, Inc.
QS
In Commercial Distribution
- 10860011629402 ()
- 00860011629405 ()
- Suture retention device
SURGI-STOP, HEMOSTATIC WOUND DRESSING, 40 PER BOX
Terlain Enterprises, Inc.
SDWD-01
In Commercial Distribution
- 10860011605703 ()
- 00860011605706 ()
- General oral wound dressing, non-animal-derived
SpineryTM Connections are cooling tubing to connect the needle handle with the cooling solution.The connection provides send and return of sterile saline water from the bag to connected needle. The single connection cooling tube is for use with one bipolar RF needle with a product code of SP-CS.
AXON SRL
SP-CS
In Commercial Distribution
- 00860011603696 ()
- Percutaneous radio-frequency ablation probe cooling tubing set
SpineryTM Connections are cooling tubing to connect the needle handle with the cooling solution.The connection provides send and return of sterile saline water from the bag to connected needle. The double connection cooling tube is for use with two bipolar RF needles with a product code of SP-CD.
AXON SRL
SP-CD
In Commercial Distribution
- 00860011603627 ()
- Percutaneous radio-frequency ablation probe cooling tubing set
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI1005
In Commercial Distribution
- 00860011603610 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI0704
In Commercial Distribution
- 00860011603603 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar