SEARCH RESULTS FOR: gs1(9 results)
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
8.0x60mm
In Commercial Distribution
- 00195451000287 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 8.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL8060
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
7.0x60mm
In Commercial Distribution
- 00195451000270 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 7.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL7060
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.5x60mm
In Commercial Distribution
- 00195451000263 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 6.5 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL6560
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.0x60mm
In Commercial Distribution
- 00195451000256 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 6.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL6060
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.5x60mm
In Commercial Distribution
- 00195451000249 ()
- Catheter Length: 135 Centimeter
- Balloon Diameter: 5.5 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL5560
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.0x60mm
In Commercial Distribution
- 00195451000232 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 5.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL5060
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.5x60mm
In Commercial Distribution
- 00195451000225 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 4.5 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL4560
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.0x60mm
In Commercial Distribution
- 00195451000218 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 4.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL4060
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
3.5x60mm
In Commercial Distribution
- 00195451000201 ()
- Catheter Working Length: 135 Centimeter
- Balloon Diameter: 3.5 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.078 Inch
- Guidewire Diameter: 0.014 Inch
M5PIVL3560
- Intravascular lithotripsy system balloon catheter, peripheral
- Medical equipment/instrument drape, single-use
1