Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

microTargeting(TM) Electrode, differential, sterile, platinum/iridium, glass insulated
FHC, INC.
MTDPBP(LS)(LS3)-00326
In Commercial Distribution

  • 10873263003265 ()
  • 00873263003268 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 291.5 Millimeter
  • Outer Diameter: 0.86 Millimeter
  • Length: 273.5 Millimeter
MTDPBP(LS)(LS3)

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(Z), for Nexframe(R) and STar(R) Drive
FHC, INC.
5705Z-00289
In Commercial Distribution

  • 10873263002893 ()
  • 00873263002896 ()

  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 227.2 Millimeter
  • Length: 242.2 Millimeter
5705Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Nexframe(R) and STar Drive
FHC, INC.
5705L-00283
In Commercial Distribution

  • 10873263002831 ()
  • 00873263002834 ()

  • Length: 227.2 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 242.2 Millimeter
  • Impedance: Megaohms
5705L

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(Z), for use with Nexframe(R)
FHC, INC.
5005Z-00277
In Commercial Distribution

  • 10873263002770 ()
  • 00873263002773 ()

  • Impedance: Megaohms
  • Length: 234.2 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
5005Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Nexframe(R)
FHC, INC.
5005L-00273
In Commercial Distribution

  • 10873263002732 ()
  • 00873263002735 ()

  • Length: 249.2 Millimeter
  • Length: 10 Millimeter
  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
5005L

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.Zap(Z), for use with Platform
FHC, INC.
44975Z-00267
In Commercial Distribution

  • 10873263002671 ()
  • 00873263002674 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 205.72 Millimeter
  • Length: 10 Millimeter
  • Length: 220.72 Millimeter
44975Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Platform
FHC, INC.
44975L-00263
In Commercial Distribution

  • 10873263002633 ()
  • 00873263002636 ()

  • Impedance: Megaohms
  • Length: 220.72 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 205.72 Millimeter
44975L

  • Depth electrode
microTargeting(TM) Electrode, 1x, sterile, R.ZAP, Platform
FHC, INC.
44970R-00259
In Commercial Distribution

  • 10873263002596 ()
  • 00873263002599 ()

  • Length: 205.72 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 220.72 Millimeter
  • Length: 10 Millimeter
44970R

  • Depth electrode
microTargeting(TM) Electrode, 1x, sterile, single, D.ZAP(Z), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685Z-00254
In Commercial Distribution

  • 10873263002541 ()
  • 00873263002544 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34685Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, single, D.ZAP(L), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685L-00252
In Commercial Distribution

  • 10873263002527 ()
  • 00873263002520 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
34685L

  • Depth electrode
microTargeting(TM) Electrode, differential, sterile, single, 1 Meg for use with Frame and STar or MT Drive
FHC, INC.
34680R-00250
In Commercial Distribution

  • 10873263002503 ()
  • 00873263002506 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
34680R

  • Depth electrode
microTargeting(TM) Electrode, sterile, 1x, array, D.ZAP(Z) for use with Frame and STar or MT Drive
FHC, INC.
22675Z-00246
In Commercial Distribution

  • 10873263002466 ()
  • 00873263002469 ()

  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
22675Z

  • Depth electrode
microTargeting Array Electrode, 1x, sterile, D.ZAP(L) for use with Frame, STar or MT Drive
FHC, INC.
22675L-00244
In Commercial Distribution

  • 10873263002442 ()
  • 00873263002445 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
22675L

  • Depth electrode
microTargeting Array Electrode, sterile, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
22670R-00242
In Commercial Distribution

  • 10873263002428 ()
  • 00873263002421 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
22670R

  • Depth electrode
microTargeting(TM) Electrode, sterile, 5x, D.ZAP(L), for use with Platform
FHC, INC.
MTDPLP(PA)(MP1)-00640
In Commercial Distribution

  • 10873263006402 ()
  • 00873263006405 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.5 Millimeter
  • Length: 220.72 Millimeter
  • Length: 215.72 Millimeter
  • Length: 10 Millimeter
MTDPLP(PA)(MP1)

  • Depth electrode
microTargeting(TM) Electrode, array, differential, 1 Meg, sterile, for Nexframe
FHC, INC.
MER-5000T-00504
In Commercial Distribution

  • 10873263005047 ()
  • 00873263005040 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 244.22 Millimeter
  • Length: 234.22 Millimeter
MER-5000T

  • Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, DZAP(L), sterile
FHC, INC.
MTSWLP(JN)(JN1)-00492
In Commercial Distribution

  • 10873263004927 ()
  • 00873263004920 ()

  • Impedance: Megaohms
  • Length: 251.4 Millimeter
  • Length: 278.4 Millimeter
  • Length: 25 Millimeter
  • Outer Diameter: 0.77 Millimeter
MTSWLP(JN)(JN1)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SL2)-00464
In Commercial Distribution

  • 10873263004644 ()
  • 00873263004647 ()

  • Length: 10 Millimeter
  • Length: 274.65 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 258 Millimeter
MTDWZP(NS)(SL2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SK2)-00462
In Commercial Distribution

  • 10873263004620 ()
  • 00873263004623 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 243.65 Millimeter
  • Length: 227 Millimeter
MTDWZP(NS)(SK2)

  • Depth electrode
microTargeting(TM) Electrode, differential, platinum/iridium, epoxylite insulated, sterile, D.ZAP(Z)
FHC, INC.
MTDPZP(NS)(SL2)-00358
In Commercial Distribution

  • 10873263003586 ()
  • 00873263003589 ()

  • Impedance: Megaohms
  • Length: 258 Millimeter
  • Length: 274.65 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
MTDPZP(NS)(SL2)

  • Depth electrode
PS, MIS-Tower Reduction, Cannulated Dual Lead 8.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-850-025
In Commercial Distribution

  • 00814008029419 ()

  • Length: 25 Millimeter
  • Outer Diameter: 8.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-750-025
In Commercial Distribution

  • 00814008029334 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-650-025
In Commercial Distribution

  • 00814008029259 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 5.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-550-025
In Commercial Distribution

  • 00814008029174 ()

  • Length: 25 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 8.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-850-025
In Commercial Distribution

  • 00814008028917 ()

  • Length: 25 Millimeter
  • Outer Diameter: 8.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 4.75X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-475-025
In Commercial Distribution

  • 00814008028597 ()

  • Length: 25 Millimeter
  • Outer Diameter: 4.75 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 8.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-850-025
In Commercial Distribution

  • 00814008028412 ()

  • Length: 25 Millimeter
  • Outer Diameter: 8.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 5.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-550-025
In Commercial Distribution

  • 00814008028177 ()

  • Length: 25 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 4.75X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-475-025
In Commercial Distribution

  • 00814008028092 ()

  • Length: 25 Millimeter
  • Outer Diameter: 4.75 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-750-025
In Commercial Distribution

  • 00814008027835 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-650-025
In Commercial Distribution

  • 00814008027750 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 8.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-850-025
In Commercial Distribution

  • 00814008027064 ()

  • Length: 25 Millimeter
  • Outer Diameter: 8.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 8.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-850-025
In Commercial Distribution

  • 00814008026883 ()

  • Length: 25 Millimeter
  • Outer Diameter: 8.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-025
In Commercial Distribution

  • 00814008026807 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-025
In Commercial Distribution

  • 00814008026722 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-025
In Commercial Distribution

  • 00814008026647 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-025
In Commercial Distribution

  • 00814008026562 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 5.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-550-025
In Commercial Distribution

  • 00814008026494 ()

  • Length: 25 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 5.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-550-025
In Commercial Distribution

  • 00814008026418 ()

  • Length: 25 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-025
In Commercial Distribution

  • 00814008026326 ()

  • Length: 25 Millimeter
  • Outer Diameter: 4.75 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile