SEARCH RESULTS FOR: 跨境出海推广费用价格多少🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(2286 results)
7mm-10mm x 10mm x 24mm PLIF ASSY (Sterile)
Xtant Medical Holdings, Inc.
X092-071024-STR
Not in Commercial Distribution
- M697X092071024STR0 ()
- M697X092071024STR1 ()
- Length: 24 Millimeter
- Height 7-10 mm
- Width: 10 Millimeter
- Metallic spinal interbody fusion cage
7mm-10mm x 10mm x 24mm PLIF ASSY
Xtant Medical Holdings, Inc.
X092-071024
Not in Commercial Distribution
- M697X0920710240 ()
- M697X0920710241 ()
- Length: 24 Millimeter
- Width: 10 Millimeter
- Height 7-10 mm
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-15-24-00
In Commercial Distribution
- 00813210020115 ()
- Length: 24 Millimeter
- Outer Diameter: 15 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-14-24-00
In Commercial Distribution
- 00813210020108 ()
- Length: 24 Millimeter
- Outer Diameter: 14 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-12-24-00
In Commercial Distribution
- 00813210020092 ()
- Length: 24 Millimeter
- Outer Diameter: 12 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-13-24-00
In Commercial Distribution
- 00813210020085 ()
- Length: 24 Millimeter
- Outer Diameter: 13 Micrometer
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-11-24-00
In Commercial Distribution
- 00813210020078 ()
- Length: 24 Millimeter
- Outer Diameter: 11 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-15-24-00
In Commercial Distribution
- 00813210020023 ()
- Length: 24 Millimeter
- Outer Diameter: 15 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-13-24-00
In Commercial Distribution
- 00813210020016 ()
- Length: 24 Millimeter
- Outer Diameter: 13 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-11-24-00
In Commercial Distribution
- 00813210020009 ()
- Length: 24 Millimeter
- Outer Diameter: 11 Millimeter
- Metallic spinal interbody fusion cage