SEARCH RESULTS FOR: 出海品牌推广策略研究🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(2303 results)
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-12-24-00
In Commercial Distribution
- 00813210020092 ()
- Length: 24 Millimeter
- Outer Diameter: 12 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-13-24-00
In Commercial Distribution
- 00813210020085 ()
- Length: 24 Millimeter
- Outer Diameter: 13 Micrometer
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift-LX Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-LX is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-LX is designed to be implanted bi-laterally via a PLIF or TLIF approach, and may be implanted with or without supplemental fixation.
Wenzel Spine, Inc.
CIE3-11-24-00
In Commercial Distribution
- 00813210020078 ()
- Length: 24 Millimeter
- Outer Diameter: 11 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-15-24-00
In Commercial Distribution
- 00813210020023 ()
- Length: 24 Millimeter
- Outer Diameter: 15 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-13-24-00
In Commercial Distribution
- 00813210020016 ()
- Length: 24 Millimeter
- Outer Diameter: 13 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-11-24-00
In Commercial Distribution
- 00813210020009 ()
- Length: 24 Millimeter
- Outer Diameter: 11 Millimeter
- Metallic spinal interbody fusion cage
Interbody Fusion Device 12 Degree Large 17mm
TITAN SPINE, LLC
2312-0217-S
Not in Commercial Distribution
- M68223120217S0 ()
- Lordotic Angle 12 Deg
- Height: 17 Millimeter
- Angle: 12 degree
- Depth: 24 Millimeter
- width(MLxAP), 36 x 24, mm
- Width: 36 Millimeter
2312-0217-S
- Metallic spinal interbody fusion cage
Interbody Fusion Device nanoLOCK Surface Technology 12 Degree Large 17mm
TITAN SPINE, LLC
2312-0217-N
Not in Commercial Distribution
- M68223120217N0 ()
- Height: 17 Millimeter
- Lordotic Angle 12 Deg
- width(MLxAP), 36 x 24, mm
- Angle: 12 degree
- Width: 36 Millimeter
- Depth: 24 Millimeter
2312-0217-N
- Metallic spinal interbody fusion cage
Interbody Fusion Device 12 Degree Large 17mm
TITAN SPINE, LLC
2312-0217
Not in Commercial Distribution
- M682231202170 ()
- Lordotic Angle 12 Deg
- Height: 17 Millimeter
- Width: 36 Millimeter
- Angle: 12 degree
- width(MLxAP), 36 x 24, mm
- Depth: 24 Millimeter
2312-0217
- Metallic spinal interbody fusion cage
Interbody Fusion Device 12 Degree Large 16mm
TITAN SPINE, LLC
2312-0216-S
Not in Commercial Distribution
- M68223120216S0 ()
- Height: 16 Millimeter
- Lordotic Angle 12 Deg
- Width: 36 Millimeter
- Angle: 12 degree
- Depth: 24 Millimeter
- width(MLxAP), 36 x 24, mm
2312-0216-S
- Metallic spinal interbody fusion cage