SEARCH RESULTS FOR: 新茶直播(下载网址:K782.com).5mi587t9.x视频(打开网站:K782.com).m16t(377857 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
BTE-TRT
audifon GmbH & Co. KG
arriva X TRT
Not in Commercial Distribution
- EADF004658295731517201 ()
004658-2957-315-1720
- Air-conduction hearing aid, behind-the-ear
BTE-TRT
audifon GmbH & Co. KG
arriva X TRT
Not in Commercial Distribution
- EADF004658295731317201 ()
004658-2957-313-1720
- Air-conduction hearing aid, behind-the-ear
BTE-TRT
audifon GmbH & Co. KG
arriva X TRT
Not in Commercial Distribution
- EADF004658295731117201 ()
004658-2957-311-1720
- Air-conduction hearing aid, behind-the-ear
The g.Estim FES is a programmable constant-current stimulator that can deliver electrical pulses with alternating polarities, lengths, amplitudes as well as trains of such pulses. The applied part is galvanic isolated. The stimulator is powered by a combination of USB bus-power and battery power. The host computer must use Microsoft Windows. The stimulator is controlled via a software API that uses a USB connection. A host application can be situated on top of the API and can control the stimulator.
g.tec medical engineering GmbH
TD 1.x
In Commercial Distribution
- EBCI11700 ()
1170
- Physical therapy transcutaneous neuromuscular electrical stimulation system
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
7.0 x 60mm
In Commercial Distribution
- 00195451000195 ()
- M732M5IVL70600 ()
- Catheter Working Length: 110 Centimeter
- Balloon Diameter: 7.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 7 French
- Balloon Proximal Outer Diameter (OD): 0.072 Inch
- Guidewire Diameter: 0.014 Inch
M5IVL7060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.5 x 60mm
In Commercial Distribution
- 00195451000188 ()
- M732M5IVL65600 ()
- Catheter Working Length: 110 Centimeter
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
- Balloon Proximal Outer Diameter (OD): 0.072 Inch
- Introducer Sheath Compatibility: 7 French
- Balloon Diameter: 6.5 Millimeter
M5IVL6560
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.0 x 60mm
In Commercial Distribution
- 00195451000171 ()
- M732M5IVL60600 ()
- Balloon Diameter: 6.0 Millimeter
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French
M5IVL6060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.5 x 60mm
In Commercial Distribution
- 00195451000164 ()
- M732M5IVL55600 ()
- Introducer Sheath Compatibility: 6 French
- Catheter Working Length: 110 Centimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
- Balloon Diameter: 5.5 Millimeter
M5IVL5560
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.0 x 60mm
In Commercial Distribution
- 00195451000157 ()
- M732M5IVL50600 ()
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Diameter: 5.0 Millimeter
M5IVL5060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.5 x 60mm
In Commercial Distribution
- 00195451000140 ()
- M732M5IVL45600 ()
- Balloon Diameter: 4.5 Millimeter
- Introducer Sheath Compatibility: 6 French
- Catheter Working Length: 110 Centimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
M5IVL4560
- Intravascular lithotripsy system balloon catheter, peripheral