The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 5.0mm, Length = 40mm, Minimum Introducer Sheath = 5F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AW18-05050040
In Commercial Distribution
- 04543660025700 ()
AW18-05050040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 4.0mm, Length = 40mm, Minimum Introducer Sheath = 5F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AW18-05040040
In Commercial Distribution
- 04543660025694 ()
AW18-05040040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 14atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 8.0mm, Length = 40mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AA18-05080040
In Commercial Distribution
- 04543660025632 ()
AA18-05080040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 14atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 7.0mm, Length = 40mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AA18-05070040
In Commercial Distribution
- 04543660025625 ()
AA18-05070040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 6.0mm, Length = 40mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AA18-05060040
In Commercial Distribution
- 04543660025618 ()
AA18-05060040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 5.0mm, Length = 40mm, Minimum Introducer Sheath = 5F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AA18-05050040
In Commercial Distribution
- 04543660025601 ()
AA18-05050040
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 4.0mm, Length = 40mm, Minimum Introducer Sheath = 5F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
AA18-05040040
In Commercial Distribution
- 04543660025595 ()
AA18-05040040
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60200ER
In Commercial Distribution
- 04540778175778 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 4.1 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 200 mm
- Balloon Diameter; 6.0 mm
BD-Q60200ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50200ER
In Commercial Distribution
- 04540778175754 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 4.1 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 200 mm
- Balloon Diameter; 5.0 mm
BD-Q50200ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40200ER
In Commercial Distribution
- 04540778175730 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 200 mm
- Balloon Diameter; 4.0 mm
BD-Q40200ER
- Peripheral angioplasty balloon catheter, basic