SEARCH RESULTS FOR: ("源头企业签名[Contact Telegram: duo785].hfs")(1623 results)
Prostiva RF Therapy Hand Piece
Urologix LLC
8929
In Commercial Distribution
- M87689290 ()
- Rigid optical cystoscope
- Urological irrigation set
- Electrosurgical return electrode, single-use, sterile
- Endoscopic electrosurgical handpiece/electrode, monopolar, single-use
KamDoy Rx Skin Emulsion is indicated as a prescription topical skin care emulsion to manage and relieve the burning and itching experienced with various types of dermatoses, including atopic and allergic contact dermatitis. KamDoy Rx Skin Emulsion helps maintain a moist wound and skin environment, which is beneficial to the healing process.
ALVIX LABORATORIES, LLC
FP1012-1
In Commercial Distribution
- 00315455956612 ()
- Skin osmotic dressing, non-sterile
The Integra Total Foot System open wedge plate is used for fixation for a variety of proximal metatarsal osteotomies. The stem is deepened and tapered for distraction of osteotomy during insertion and solid contact against cortical bone. It contains distal screw holes that are narrowed for an anatomic fit along the distal metatarsal.
Ascension Orthopedics, Inc.
2832100
Not in Commercial Distribution
- 10381780119173 ()
- M26828321001 ()
- 26. 52 mm L x 15 mm W
2832100
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
The Sono TT Ultrasonic Flowcomputer in combination with an ultrasonic clamp-on Transducer is indicated for the contact less volumetric measurement of liquid flowing through tubing systems. The measurement principle is the ultrasound transit-time method.
The medical use of the device is appropriate in the following extracorporeal procedures:
- Cardio-pulmonary bypass, membrane-oxygenation, hemodialysis, hemofiltration, plasmapheresis
- Perfusion, infusion, transfusion
- Several shunt-applications
em-tec GmbH
11924
In Commercial Distribution
- 04062114000297 ()
11924
- Noninvasive vascular ultrasound system, line-powered
The Sono TT Ultrasonic Flowcomputer in combination with an ultrasonic clamp-on
Transducer is indicated for the contact less volumetric measurement of liquid flowing through
tubing systems. The measurement principle is the ultrasound transit-time method.
The medical use of the device is appropriate in the following extracorporeal procedures:
- Cardio-pulmonary bypass, membrane-oxygenation, hemodialysis, hemofiltration,
plasmapheresis
- Perfusion, infusion, transfusion
- Several shunt-applications
em-tec GmbH
11945
In Commercial Distribution
- 04062114000280 ()
11945
- Noninvasive vascular ultrasound system, line-powered
The Sono TT Ultrasonic Flowcomputer in combination with an ultrasonic clamp-on Transducer is indicated for the contact less volumetric measurement of liquid flowing through tubing systems. The measurement principle is the ultrasound transit-time method.
The medical use of the device is appropriate in the following extracorporeal procedures:
- Cardio-pulmonary bypass, membrane-oxygenation, hemodialysis, hemofiltration, plasmapheresis
- Perfusion, infusion, transfusion
- Several shunt-applications
em-tec GmbH
11923
In Commercial Distribution
- 04062114000266 ()
11923
- Noninvasive vascular ultrasound system, line-powered
The Integra Total Foot System open wedge plate is used for fixation for a variety of proximal metatarsal osteotomies. The stem is deepened and tapered for distraction of osteotomy during insertion and solid contact against cortical bone. It contains distal screw holes that are narrowed for an anatomic fit along the distal metatarsal and stems moved proximally on plate to minimize potential interference with proximal joint
Ascension Orthopedics, Inc.
2832154
In Commercial Distribution
- M26928321541 ()
- 10381780119821 ()
- 26.52 mm L x 15.0 mm W x 4.5 mm H; 4.5 mm stem
2832154
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
The Integra Total Foot System open wedge plate is used for fixation for a variety of proximal metatarsal osteotomies. The stem is deepened and tapered for distraction of osteotomy during insertion and solid contact against cortical bone. It contains distal screw holes that are narrowed for an anatomic fit along the distal metatarsal and stems moved proximally on plate to minimize potential interference with proximal joint
Ascension Orthopedics, Inc.
2832153
In Commercial Distribution
- M26928321531 ()
- 10381780119814 ()
- 26.52 mm L x 15.0 mm W x 4.5 mm H; 3.5 mm stem
2832153
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
The Integra Total Foot System open wedge plate is used for fixation for a variety of proximal metatarsal osteotomies. The stem is deepened and tapered for distraction of osteotomy during insertion and solid contact against cortical bone. It contains distal screw holes that are narrowed for an anatomic fit along the distal metatarsal and stems moved proximally on plate to minimize potential interference with proximal joint
Ascension Orthopedics, Inc.
2832152
In Commercial Distribution
- M26928321521 ()
- 10381780119807 ()
- 26.52 mm L x 15.0 mm W x 4.5 mm H; 2.5 mm stem
2832152
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
The Integra Total Foot System open wedge plate is used for fixation for a variety of proximal metatarsal osteotomies. The stem is deepened and tapered for distraction of osteotomy during insertion and solid contact against cortical bone. It contains distal screw holes that are narrowed for an anatomic fit along the distal metatarsal and stems moved proximally on plate to minimize potential interference with proximal joint
Ascension Orthopedics, Inc.
2832106
Not in Commercial Distribution
- 10381780119227 ()
- M26828321061 ()
- 26.52 mm L x 15 mm W x 4.5 mm H; 6 mm stem
2832106
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile