SEARCH RESULTS FOR: (*Imitation Laguna College of Art*)(285803 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The standard Kompressor Compression Screw is a two-piece fixation device intended for the use in the reduction, stabilization, and internal fixation of bone fractures. The 2-piece design incorporates the use of a leading and trailing screw component. The implant utilizes a variance in thread pitch between the leading and trailing portions of the screw to reduce and fix fracture fragments, and is available in a variety of sizes to accommodate various fracture types and sites.
Ascension Orthopedics, Inc.
210418
Not in Commercial Distribution

  • M2482104181 ()
  • 10381780065609 ()

  • 4.0 mm dia x 18.0 mm L
210418

  • Orthopaedic bone screw, non-bioabsorbable, sterile
The standard Kompressor Compression Screw is a two-piece fixation device intended for the use in the reduction, stabilization, and internal fixation of bone fractures. The 2-piece design incorporates the use of a leading and trailing screw component. The implant utilizes a variance in thread pitch between the leading and trailing portions of the screw to reduce and fix fracture fragments, and is available in a variety of sizes to accommodate various fracture types and sites.
Ascension Orthopedics, Inc.
210416
Not in Commercial Distribution

  • M2482104161 ()
  • 10381780065593 ()

  • 4.0 mm dia x 16.0 mm L
210416

  • Orthopaedic bone screw, non-bioabsorbable, sterile
The standard Kompressor Compression Screw is a two-piece fixation device intended for the use in the reduction, stabilization, and internal fixation of bone fractures. The 2-piece design incorporates the use of a leading and trailing screw component. The implant utilizes a variance in thread pitch between the leading and trailing portions of the screw to reduce and fix fracture fragments, and is available in a variety of sizes to accommodate various fracture types and sites.
Ascension Orthopedics, Inc.
210414
Not in Commercial Distribution

  • M2482104141 ()
  • 10381780065586 ()

  • 4.0 mm dia x 14.0 mm L
210414

  • Orthopaedic bone screw, non-bioabsorbable, sterile
The PARK 1 combines three measuring functions in one unit. Auto-Refractometer An infrared light source projects measuring light onto the retina of the eye from where it is reflected back to the shutter location. Sensitive sensor chips, or CCD cameras now register the deviation of the reflected light from the shutter location. The deviation depends on the ametropia. From that, an integrated microcomputer calculates the ametropia in D, based on the sphere, cylinder and cylinder axis position. 1 Measuring ocular / Patient eyepiece 4 Chin rest 2 Keratometer ring 5 Marking for the eye height 3 Pachycam camera glass cover Keratometer To determine the curvature of the cornea, a reflected image of the cornea is captured by a camera sensor and is measured. The reflection of test marks and of a ring is used as the reflected image. This allows the central radii of the cornea to be determined. Pachymeter The pachymetry principle uses Scheimpflug images of the cornea, which are analysed by a built-in computer. 600 Absolute data points are evaluated with the Scheimpflug image. The measuring range lies on a 4 mm slit through the apex. The slit light illuminates a sectional plane from the front surface of the cornea to the back surface. The transparent cells of the cornea scatter the slit light such that the sectional plane appears as if it were self-luminous. This is captured at an angle of 45° through the pupil by a camera, whereby the image plane of the camera is also tilted 45° to the optical axis of the camera lens, in order to sharply focus the light-scattering cornea plane onto the image plane of the camera (Scheimpflug image). Thanks to this arrangement, sharp sectional images of the cornea can be attained.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
65000
In Commercial Distribution

  • 04049584000217 ()

  • Weight: 12 Kilogram
  • Depth: 530 Millimeter
  • Width: 538 Millimeter
  • Height: 265 Millimeter


  • Ophthalmic refractometer, manual
Single use coring needle for retrieval of tissue samples. It is placed through a flexible bronchoscope.
BRONCUS MEDICAL INC.
10005-2
In Commercial Distribution

  • 00856571007210 ()

  • Needle Gauge: 18 Gauge
10005-2

  • Soft-tissue biopsy needle, single-use
Single use coring needle for retrieval of tissue samples. It is placed through a flexible bronchoscope.
BRONCUS MEDICAL INC.
10005-1
In Commercial Distribution

  • 00856571007012 ()

  • Needle Gauge: 18 Gauge
10005-1

  • Soft-tissue biopsy needle, single-use
Stationary digital specimen x-ray system with 23x29cm imager intended for the examination of Core Biopsy excisions.
FAXITRON BIOPTICS, LLC
PathVision 23x29 cm
In Commercial Distribution

  • 00857069006050 ()


  • Stationary specimen x-ray system, digital
Camco Quik Stain Buffered differential stains used in the staining of blood smears for hematological study.
CAMBRIDGE DIAGNOSTIC PRODUCTS INC
210
In Commercial Distribution

  • 00691573210035 ()

  • Total Volume: 1 Quart
210

  • Romanowsky stain IVD, kit
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/or Automated Procedures.
STANBIO LABORATORY, L.P.
2930-500
In Commercial Distribution

  • 00657498000472 ()
2930-500

  • Alanine aminotransferase (ALT) IVD, kit, enzyme spectrophotometry
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/or Automated Procedures.
STANBIO LABORATORY, L.P.
2930-430
In Commercial Distribution

  • 00657498000465 ()
2930-430

  • Alanine aminotransferase (ALT) IVD, kit, enzyme spectrophotometry
< 1 ... 215 216 217 218 219 ... 1000 >