The NIDEK Specular Microscope CEM-530 provides non-contact, high magnification image capture of endothelium enabling observation of the size and shape of cells. Information such as the number of endothelial cells, cell density, and cell area is analyzed through the captured images. The captured images and analysis results of endothelium are used for intraocular or corneal surgery, postoperative follow-up, and corneal observation such as for endothelial disorders or the corneal state of patients who wear extended-wear contact lenses. Observation is possible in the central area (visual angle: 5°) and peripheral area (visual angle: 27°) using a periphery capture function as well as in the center of the cornea. The captured images and analysis results can be printed on the built-in printer or optional video printer, or output to an external device over LAN connection.
NIDEK CO.,LTD.
CEM-530
In Commercial Distribution

  • 04987669100530 ()


  • Optical pachymeter
  • Direct ophthalmoscope, line-powered
The Televisit software is intended for the purposes of collecting physiological data such as: Non-Invasive Blood Pressure; Pulse Oximetry, Temperature and Breath Sounds (Auscultation), Spirometer, Glucometer and E.C.G. The intended use of the Televisit software is in hospital/clinical environments with established specialized care providing access to each patient in their home and/or local community health center. Televisit software is a non-invasive medical device, which does not flag any abnormal results from the medical device inputs. The Televisit software does not monitor, assess or diagnose a disease, a disorder, or an abnormal physical state. The intended use for the software is data acquisition and collection only, with no treatment function or danger to the end user. The data obtained from Televisit software can be used only as an aid in the diagnosis and treatment of the patient.
Primonics (2006) Inc
TVS
In Commercial Distribution

  • 00628250477016 ()


  • Pulse oximeter, line-powered
AIR SUPPLY Air supply units may be compatible with PremierPro™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING Disposable Models The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
SVS LLC
3703
In Commercial Distribution

  • 10818566019193 ()
  • 00818566019196 ()

  • Length: 50 Inch
3703

  • Patient transfer system, powered
AIR SUPPLY Air supply units may be compatible with PremierPro™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING Disposable Models The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
SVS LLC
3702
In Commercial Distribution

  • 00818566019189 ()
  • 10818566019186 ()

  • Length: 39 Inch


  • Patient transfer system, powered
INTENDED USE/ CONTRAINDICATIONS PremierPro™ Air Transfer Mats are indicated for patients: Who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. PRECAUTIONS & WARNINGS Use two or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg). AIR SUPPLY Air supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
SVS LLC
3711
In Commercial Distribution

  • 10818566019216 ()
  • 00818566019219 ()

  • Length: 39 Inch
3711

  • Patient transfer system, powered
INTENDED USE/ CONTRAINDICATIONS PremierPro™ Air Transfer Mats are indicated for patients: Who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. PRECAUTIONS & WARNINGS Use two or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg). AIR SUPPLY Air supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
SVS LLC
3710
In Commercial Distribution

  • 10818566019209 ()
  • 00818566019202 ()

  • Length: 34 Inch
3710

  • Patient transfer system, powered
INTENDED USE/ CONTRAINDICATIONS PremierPro™ Air Transfer Mats are indicated for patients: Who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. PRECAUTIONS & WARNINGS Use two or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg). AIR SUPPLY Air supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit's operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit's operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
SVS LLC
3700
In Commercial Distribution

  • 00818566019165 ()
  • 10818566019162 ()

  • Length: 28 Inch
3700

  • Patient transfer system, powered