SEARCH RESULTS FOR: (*bitcoin mining hardware comparison馃挷itenthusiasts.com馃挷Cryptocurrency*)(6601 results)
Computer assisted reading tools designed to aid the radiologist in the detection of pulmonary nodules during review of CT examinations of the chest.
Infervision US Inc
2.1.2.1
In Commercial Distribution
- 00850003095004 ()
- X-ray image interpretive software
- Diagnostic x-ray digital imaging system workstation
Cassette Printer with AutoLoader
SAKURA FINETEK U.S.A., INC.
9020
In Commercial Distribution
- 00615233082374 ()
9020
- Cell morphology analyser IVD, automated/semi-automated
- Computed radiography digital imaging scanner
BeamSite™ is a camera system that enables live visualization of the treatment beam on a patient during radiotherapy. It is an optically based system that is non-patient contacting and produces no radiation. When the treatment beam is on, BeamSite captures images of Cherenkov light emitted from the patient’s skin during radiotherapy to provide an optical map of the treatment beam on the patient. When the treatment beam is off, the system provided continuous background images of the treatment area under ambient light illumination. The BeamSite system consists of a camera, a workstation with preinstalled BeamSite software, and a monitor to be used by clinical radiotherapy teams to a) visually observe the patient and the Cherenkov light emitted from irradiated surface anatomy, and b) review the treatment images, if necessary.
Doseoptics LLC
BeamSite
In Commercial Distribution
- 00860009184503 ()
- Radiation therapy software
- Radiation therapy system workstation, multi-purpose
The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x Assembly Kit consists of a combination of the following components, some or all of which are not yet assembled: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 30382 rev1
In Commercial Distribution
- 00855846007252 ()
30382
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x Assembly Kit consists of a combination of the following components, some or all of which are not yet assembled: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 30381 rev1
In Commercial Distribution
- 00855846007245 ()
30381
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The Mobile Arm Rehabilitation Kit version 2 (MARK2) is a kit containing two (left and right) MyoPro upper extremity limb orthoses. A MyoPro upper extremity limb orthosis is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MARK2 product consists of a combination of the following components: shoulder harnesses, adjustable limb orthoses (braces), powered elbow orthoses with surface electromyography (EMG) sensors, static or manually set multi-articulating wrists (MAW), static hand orthoses or powered hand orthoses with EMG sensors, an interchangeable battery with a separate recharging station, an MTS chafe with loop for anti-rotation strap, a laptop, and a product carrying case/bag.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. A MyoPro device filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate and complete desired motions.
Myomo, Inc.
MARK2 29860
In Commercial Distribution
- 00855846007238 ()
MARK2 29860
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 29858 rev1
In Commercial Distribution
- 00855846007221 ()
29858
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 29857 rev1
In Commercial Distribution
- 00855846007214 ()
29857
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 28463 rev1
In Commercial Distribution
- 00855846007160 ()
28463
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 28462 rev1
In Commercial Distribution
- 00855846007153 ()
28462
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis