SEARCH RESULTS FOR: (*cryptocurrency exchange hong kong馃挷itenthusiasts.com馃挷Enthusiasts*)(30983 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 6.0mm, Length = 100mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14560100
In Commercial Distribution
- 04543660026462 ()
LW18-14560100
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 5.0mm, Length = 150mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14550150
In Commercial Distribution
- 04543660026455 ()
LW18-14550150
- Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 5.0mm, Length = 100mm, Minimum Introducer Sheath = 6F.
The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14550100
In Commercial Distribution
- 04543660026448 ()
LW18-14550100
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40040ER
In Commercial Distribution
- 04540778175013 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 40 mm
- Balloon Diameter; 4.0 mm
BD-Q40040ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30040ER
In Commercial Distribution
- 04540778174993 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 40 mm
- Balloon Diameter; 3.0 mm
BD-Q30040ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25040ER
In Commercial Distribution
- 04540778174979 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.5 mm
BD-Q25040ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20040ER
In Commercial Distribution
- 04540778174955 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.0 mm
BD-Q20040ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60020ER
In Commercial Distribution
- 04540778174931 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 6.0 mm
BD-Q60020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50020ER
In Commercial Distribution
- 04540778174917 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 5.0 mm
BD-Q50020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40020ER
In Commercial Distribution
- 04540778174894 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 4.0 mm
BD-Q40020ER
- Peripheral angioplasty balloon catheter, basic