SEARCH RESULTS FOR: ("Imitation The Queen")(1035691 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution

  • 00816101017317 ()
TO-52-CP-35

  • Orthopaedic bone screw (non-sliding)
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution

  • 00816101017300 ()
TO-52-CP-40

  • Orthopaedic fixation plate, non-bioabsorbable
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution

  • 00816101017294 ()
TO-52-CP-45

  • Orthopaedic bone screw (non-sliding)
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution

  • 00816101017287 ()
TO-52-CP-50

  • Orthopaedic bone screw (non-sliding)
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-003
In Commercial Distribution

  • 10810098650295 ()
4340

  • Implantable sleep apnoea treatment system, respiration-sensing
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-001
Not in Commercial Distribution

  • 00855728005796 ()
4340

  • Implantable sleep apnoea treatment system, respiration-sensing
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-001
In Commercial Distribution

  • 10855728005793 ()
4340

  • Implantable sleep apnoea treatment system, respiration-sensing
The Prosthetic Screws provided for the Elos Accurate Hybrid Base are used to secure the final prosthetic restoration to the implant. The Prosthetic Screws have a hexalobular driver connection interface.
Elos Medtech Pinol A/S
AS-NGMM1610A-1
In Commercial Distribution

  • 05712821010544 ()
AS-NGMM1610A-1

  • Dental prosthesis/implant abutment screw
The Prosthetic Screws provided for the Elos Accurate Hybrid Base are used to secure the final prosthetic restoration to the implant. The Prosthetic Screws have a hexalobular driver connection interface.
Elos Medtech Pinol A/S
AS-HETM2008A-1
In Commercial Distribution

  • 05712821010537 ()
AS-HETM2008A-1

  • Dental prosthesis/implant abutment screw
The Prosthetic Screws provided for the Elos Accurate Hybrid Base are used to secure the final prosthetic restoration to the implant. The Prosthetic Screws have a hexalobular driver connection interface.
Elos Medtech Pinol A/S
AS-HETM1610A-1
In Commercial Distribution

  • 05712821010520 ()
AS-HETM1610A-1

  • Dental prosthesis/implant abutment screw
< 1 ... 213 214 215 216 217 ... 1000 >