Gravity Compensating Accessory, Medium Pressure Range (Yellow)
NATUS MEDICAL INCORPORATED
NT903435
In Commercial Distribution


  • Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 200-250mmH2O
NT903435

  • Ventriculo-peritoneal/atrial shunt
The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
903430
Not in Commercial Distribution

  • 10381780033516 ()
  • M2729034301 ()

  • Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 140-170mmH2O
903430

  • Ventriculo-peritoneal/atrial shunt
The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
903435
Not in Commercial Distribution

  • 10381780033523 ()
  • M2729034351 ()

  • Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 200-250mmH2O
903435

  • Ventriculo-peritoneal/atrial shunt
9.6F PLASTIC Pro-Fuse® CT PORT W/ATTACHABLECT PORT W/AT SILICONE CATHETER W/5FSILICONE C Micro-Stick®INTRODUCER SE
Medical Components, Inc.
MIPP96AFS
Not in Commercial Distribution

  • 50884908148928 ()
  • 00884908148923 ()
MIPP96AFS

  • Vascular port/catheter
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-0308
In Commercial Distribution

  • 04540778176591 ()

  • Complex (Silky Soft) 10inch 3mm x 8cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-0308

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-0306
In Commercial Distribution

  • 04540778176584 ()

  • Complex (Silky Soft) 10inch 3mm x 6cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-0306

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-0304
In Commercial Distribution

  • 04540778176577 ()

  • Complex (Silky Soft) 10inch 3mm x 4cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-0304

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-02H6
In Commercial Distribution

  • 04540778176553 ()

  • Complex (Silky Soft) 10inch 2.5mm x 6cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-02H6

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-02H4
In Commercial Distribution

  • 04540778176546 ()

  • Complex (Silky Soft) 10inch 2.5mm x 4cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-02H4

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel.
KANEKA CORPORATION
390-0208
In Commercial Distribution

  • 04540778176539 ()

  • Complex (Silky Soft) 10inch 2mm x 8cm
  • Compatible Microcatheter inner diameter: 0.33 to 0.48 Millimeter
390-0208

  • Non-neurovascular embolization coil
  • Neurovascular embolization coil
< 1 ... 22 23 24 25 26 ... 1000 >