SEARCH RESULTS FOR: ("Imitation The Queen")(1035759 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The one hole cube is used to allow the fixation wire to be tensioned axially without deformation by the wire tensioner. The cube is manufactured from stainless steel.
Ascension Orthopedics, Inc.
12224222
In Commercial Distribution

  • 10381780125174 ()

  • .722 in H
12224222

  • External orthopaedic fixation system, reusable
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-019
In Commercial Distribution

  • 10810098650264 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-017
In Commercial Distribution

  • 10810098650141 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-014
In Commercial Distribution

  • 10855728005915 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-010
In Commercial Distribution

  • 10855728005762 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-008
In Commercial Distribution

  • 10855728005656 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-003
In Commercial Distribution

  • 10855728005465 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-001
In Commercial Distribution

  • 10855728005366 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3150 IPG is the next generation Implantable Pulse Generator (IPG). It contains electronics and a battery that are sealed inside a titanium case. The Model 3150 is smaller in size than the previous model (3028) and eliminates the need of an Inspire respiratory sensing lead by having a built-in sensing accelerometer in the Model 3150 generator itself. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connects to the Inspire stimulation lead. The Model 3150 introduces improved communication speed between the IPG and the external products along with enhanced security. The Inspire system stimulates the hypoglossal nerve, synchronous with the patient’s respiration cycle using closed loop sensing technology. The timed stimulation elicits a neuromuscular response from the base of the tongue thereby preventing upper airway collapse that causes airflow obstruction in many OSA patients. The Model 3150 IPG will also allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-015-001
In Commercial Distribution

  • 10855728005960 ()
3150

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Ascension® PyroCarbon Lunate is an anatomically designed lunate replacement with essentially the same shape as the native lunate bone. The Lunate implant acts as an articulating spacer to maintain the relationship of adjacent carpal bones after excision and to maintain mobility of the wrist. The articular concavity that captures the capitate is more exaggerated to enhance stability. The Lunate implant has two suture holes which allow fixation of the implant to the adjacent scaphoid and triquetrium bones to provide temporary postoperative stability while a capsuloligamentous system forms around the implant. The Ascension® Pyrocarbon Lunate is constructed of a high strength On-X® PyroCarbon layer deposited on a graphite substrate. The graphite is impregnated with tungsten making the Lunate implant radiopaque. The Ascension® PyroCarbon Lunate is intended for replacement of the lunate bone in the proximal carpal row of the wrist in the presence of Avascular necrosis (Kienboch’s disease), localized osteoarthritic, or changes in Long-Standing dislocations.
Ascension Orthopedics, Inc.
LUN71003WW
In Commercial Distribution

  • 10381780116264 ()
  • M268LUN71003WW1 ()

  • .5276in H x .6850in W; Size 3
LUN-710-03-WW

  • Carpal lunate prosthesis
< 1 ... 312 313 314 315 316 ... 1000 >