SEARCH RESULTS FOR: (*Imitation Laguna College of Art*)(1041759 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
A plate indicated for fractures and osteotomies of the distal volar radius.
CARBOFIX ORTHOPEDICS LTD
Distal Volar Radius Plate - Standard
In Commercial Distribution
- 07290109333847 ()
- Length: 90 Millimeter
- Number of Shaft Holes: 7
- Right/Left: L
PRLNN2407
- Orthopaedic fixation plate, non-bioabsorbable
A plate indicated for fractures and osteotomies of the distal volar radius.
CARBOFIX ORTHOPEDICS LTD
Distal Volar Radius Plate - Standard
In Commercial Distribution
- 07290109333830 ()
- Length: 60 Millimeter
- Number of Shaft Holes: 4
- Right/Left: R
PRRNN2404
- Orthopaedic fixation plate, non-bioabsorbable
A plate indicated for fractures and osteotomies of the distal volar radius.
CARBOFIX ORTHOPEDICS LTD
Distal Volar Radius Plate - Standard
In Commercial Distribution
- 07290109333823 ()
- Right/Left: L
- Number of Shaft Holes: 4
- Length: 60 Millimeter
PRLNN2404
- Orthopaedic fixation plate, non-bioabsorbable
A plate indicated for fractures and osteotomies of the distal volar radius.
CARBOFIX ORTHOPEDICS LTD
Distal Volar Radius Plate - Standard
In Commercial Distribution
- 07290109333816 ()
- Right/Left: R
- Number of Shaft Holes: 3
- Length: 52 Millimeter
PRRNN2403
- Orthopaedic fixation plate, non-bioabsorbable
A plate indicated for fractures and osteotomies of the distal volar radius.
CARBOFIX ORTHOPEDICS LTD
Distal Volar Radius Plate - Standard
In Commercial Distribution
- 07290109333809 ()
- Length: 52 Millimeter
- Number of Shaft Holes: 3
- Right/Left: L
PRLNN2403
- Orthopaedic fixation plate, non-bioabsorbable
External fixation system for acute dorsal fracture dislocations of the PIP joint.
Hand Biomechanics Lab Inc
FCS-400
Not in Commercial Distribution
- 00861994000229 ()
- Orthopaedic bone pin, non-bioabsorbable
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution
- 00816101017324 ()
TO-52-CP-30
- Orthopaedic fixation plate, non-bioabsorbable
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution
- 00816101017317 ()
TO-52-CP-35
- Orthopaedic bone screw (non-sliding)
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution
- 00816101017300 ()
TO-52-CP-40
- Orthopaedic fixation plate, non-bioabsorbable
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
TOBY ORTHOPAEDICS
NA
In Commercial Distribution
- 00816101017294 ()
TO-52-CP-45
- Orthopaedic bone screw (non-sliding)