SEARCH RESULTS FOR: 代办AT(112580 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Integra Contour-Flex Valve is a multi-function membrane valve with occluders and integral connectors. It is used in treatment of patients with hydrocephalus when shunting cerebrospinal fluid (CSF) from ventricles of the brain. The Contour-Flex Valve design includes a flat silicone membrane, which provides resistance to CSF flow. The Contour-Flex Valve is available in two sizes: Regular and Small. Both sizes are available in 3 pressure/flow characteristics ranges: low, medium, and high.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
11813
Not in Commercial Distribution

  • 10381780032823 ()
  • M272118131 ()

  • High Pressure at 20ml/h: 12.7-18.0cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
11813

  • Ventriculo-peritoneal/atrial shunt
The Integra Contour-Flex Valve is a multi-function membrane valve with occluders and integral connectors. It is used in treatment of patients with hydrocephalus when shunting cerebrospinal fluid (CSF) from ventricles of the brain. The Contour-Flex Valve design includes a flat silicone membrane, which provides resistance to CSF flow. The Contour-Flex Valve is available in two sizes: Regular and Small. Both sizes are available in 3 pressure/flow characteristics ranges: low, medium, and high.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
11812
Not in Commercial Distribution

  • 10381780032816 ()
  • M272118121 ()

  • Medium Pressure at 20ml/h: 6.7-11.8cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
11812

  • Ventriculo-peritoneal/atrial shunt
The Integra Contour-Flex Valve is a multi-function membrane valve with occluders and integral connectors. It is used in treatment of patients with hydrocephalus when shunting cerebrospinal fluid (CSF) from ventricles of the brain. The Contour-Flex Valve design includes a flat silicone membrane, which provides resistance to CSF flow. The Contour-Flex Valve is available in two sizes: Regular and Small. Both sizes are available in 3 pressure/flow characteristics ranges: low, medium, and high.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
11811
Not in Commercial Distribution

  • 10381780032809 ()
  • M272118111 ()

  • Low Pressure at 20ml/h: 1.2-5.8cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
11811

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve System, Regular, High Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14163
Not in Commercial Distribution


  • High Pressure at 20ml/h: 12.7-18.0cmH2O, Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Right Angle Guide 4.9mm Diam.
14163

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve System, Regular, Medium Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14162
Not in Commercial Distribution


  • Medium Pressure at 20ml/h: 6.7-11.8cmH2O, Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Right Angle Guide 4.9mm Diam.
14162

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve System, Regular, Low Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14161
Not in Commercial Distribution


  • Low Pressure at 20ml/h: 1.2-5.8cmH2O, Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Right Angle Guide 4.9mm Diam.
14161

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve and Shunt System Contour-Flex Valve System, Small, High Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14087
Not in Commercial Distribution


  • High Pressure at 20ml/h: 12.7-18.0cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
14087

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve System, Small, Medium Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14086
Not in Commercial Distribution


  • Medium Pressure at 20ml/h: 6.7-11.8cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
14086

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve and Shunt System Contour-Flex Valve System, Small, Low Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
14085
Not in Commercial Distribution


  • Low Pressure at 20ml/h: 1.2-5.8cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
14085

  • Ventriculo-peritoneal/atrial shunt
Contour-Flex Valve System, Regular, High Pressure for ventricular shunting of cerebrospinal fluid.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
12510
Not in Commercial Distribution


  • High Pressure at 20ml/h: 12.7-18.0cmH2O, Outlet Tubing 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
12510

  • Ventriculo-peritoneal/atrial shunt
< 1 ... 648 649 650 651 652 ... 1000 >