A plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
NOVOSCI CORP.
C460B
In Commercial Distribution
- B066C460B1 ()
- B066C460B5 ()
- B066C460B3 ()
- B066C460B2 ()
- B066C460B0 ()
- B066C4604 ()
C460B
- Non-ISO80369-standardized small-bore multichannel connector, single-use
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
NOVOSCI CORP.
C440S
In Commercial Distribution
- B066C440S0 ()
- B066C440S6 ()
- B066C440S5 ()
- B066C440S4 ()
- B066C440S3 ()
C440S
- Non-ISO80369-standardized small-bore multichannel connector, single-use
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
NOVOSCI CORP.
C430S
In Commercial Distribution
- B066C430S0 ()
- B066C430S6 ()
- B066C430S5 ()
- B066C430S4 ()
- B066C430S3 ()
C430S
- Non-ISO80369-standardized small-bore multichannel connector, single-use
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
7.0 x 60mm
In Commercial Distribution
- 00195451000195 ()
- M732M5IVL70600 ()
- Catheter Working Length: 110 Centimeter
- Balloon Diameter: 7.0 Millimeter
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Introducer Sheath Compatibility: 7 French
- Balloon Proximal Outer Diameter (OD): 0.072 Inch
- Guidewire Diameter: 0.014 Inch
M5IVL7060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.5 x 60mm
In Commercial Distribution
- 00195451000188 ()
- M732M5IVL65600 ()
- Catheter Working Length: 110 Centimeter
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
- Balloon Proximal Outer Diameter (OD): 0.072 Inch
- Introducer Sheath Compatibility: 7 French
- Balloon Diameter: 6.5 Millimeter
M5IVL6560
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.0 x 60mm
In Commercial Distribution
- 00195451000171 ()
- M732M5IVL60600 ()
- Balloon Diameter: 6.0 Millimeter
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French
M5IVL6060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.5 x 60mm
In Commercial Distribution
- 00195451000164 ()
- M732M5IVL55600 ()
- Introducer Sheath Compatibility: 6 French
- Catheter Working Length: 110 Centimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
- Balloon Diameter: 5.5 Millimeter
M5IVL5560
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.0 x 60mm
In Commercial Distribution
- 00195451000157 ()
- M732M5IVL50600 ()
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Diameter: 5.0 Millimeter
M5IVL5060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.5 x 60mm
In Commercial Distribution
- 00195451000140 ()
- M732M5IVL45600 ()
- Balloon Diameter: 4.5 Millimeter
- Introducer Sheath Compatibility: 6 French
- Catheter Working Length: 110 Centimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
M5IVL4560
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.0 x 60mm
In Commercial Distribution
- 00195451000133 ()
- M732M5IVL40600 ()
- Balloon Diameter: 4.0 Millimeter
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French