SEARCH RESULTS FOR: 跨境出海推广费用价格多少🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(6882 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Locking door Data Logger Foot levelers Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
W2024XSS-G-NB
In Commercial Distribution

  • B286W2024XSSGNB1 ()
W2024XSS-G-NB

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Stainless Steel door Data logger Door lock Audible and visual over-temp alarm. Keyed temperature lock for each chamber Mobile Base Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-MB
In Commercial Distribution

  • B286SWC182424MB1 ()
SWC182424-MB

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control Glass door Audible and visual over-temp alarm Keyed temperature lock for each chamber Data Logger Door Lock Foot levelers Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. Celcius UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-G-NB-C
In Commercial Distribution

  • B286SWC182424GNBC1 ()
SWC182424-G-NB-C

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control Glass door Audible and visual over-temp alarm Keyed temperature lock for each chamber Data Logger Door Lock Foot levelers Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-G-NB
In Commercial Distribution

  • B286SWC182424GNB1 ()
SWC182424-G-NB

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Data logger Door lock Audible and visual over-temp alarm. Keyed temperature lock for each chamber Mobile Base Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-G-MB
In Commercial Distribution

  • B286SWC182424GMB1 ()
SWC182424-G-MB

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Data logger Door lock Audible and visual over-temp alarm. Keyed temperature lock for each chamber 4" Base Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-G-4B
In Commercial Distribution

  • B286SWC182424G4B1 ()
SWC182424-G-4B

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Stainless Steel door Data logger Door lock Audible and visual over-temp alarm. Keyed temperature lock for each chamber 4" Base Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr. UL/CUL listed FDA Registered
M.A.C. MEDICAL INC.
SWC182424-4B
In Commercial Distribution

  • B286SWC1824244B1 ()
SWC182424-4B

  • Blanket warming cabinet, dry-heat
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ110N
Not in Commercial Distribution

  • M2729MZ110N1 ()
  • 10381780035848 ()

  • 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7)
9MZ110N

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ1011
Not in Commercial Distribution

  • 10381780035831 ()
  • M2729MZ10111 ()

  • 110cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ1011

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ101
Not in Commercial Distribution

  • 10381780035824 ()
  • M2729MZ1011 ()

  • 91cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ101

  • Peritoneal/atrial cerebrospinal fluid catheter
< 1 ... 678 679 680 681 682 ... 689 >