The Integra Ventricular Antechamber is a radiopaque component of a Cerebrospinal Fluid (CSF) shunt. The Ventricular Antechamber Kit includes a Ventricular Antechamber, a separate Straight Ventricular Catheter, featuring radiopaque Length Markings, a Right Angle Guide and a Wire Introducer. Other configurations are available: Ventricular Antechamber alone; Ventricular Antechamber with an integrated Right Angle Ventricular Catheter (Integral Ventricular Reservoir).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
999015
Not in Commercial Distribution
- 10381780034490 ()
- M2729990151 ()
- Vent. Antechamber 0.3ml. Internal Volume, Vent. Cath. 3cm Length x 2.7mm O.D. x 1.4mm I.D. (F8)
999015
- Intracerebral infusion/drainage catheter, long-term
The Integra Ventricular Antechamber is a radiopaque component of a Cerebrospinal Fluid (CSF) shunt. The Ventricular Antechamber Kit includes a Ventricular Antechamber, a separate Straight Ventricular Catheter, featuring radiopaque Length Markings, a Right Angle Guide and a Wire Introducer. Other configurations are available: Ventricular Antechamber alone; Ventricular Antechamber with an integrated Right Angle Ventricular Catheter (Integral Ventricular Reservoir).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
999014
Not in Commercial Distribution
- 10381780034483 ()
- M2729990141 ()
- Vent. Antechamber 0.3ml Internal Volume, Right Angle Guide 4.9mm Diam., Straight Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8)
999014
- Intracerebral infusion/drainage catheter, long-term
The Cyst Puncture Catheter is a 25 cm long, radiopaque silicone elastomer catheter with a tapered end terminating in a tip with a hole. The catheter features radiopaque length markings at 5, 10 and 15 cm from the tip. The catheter has 2 drainage holes, 180 degrees apart, located 5 mm from the tip. The proximity of the holes near the tip ensures that the holes will not extend outside small cysts. Each catheter is supplied with 2 stylets: a blunt-ended stylet and a sharp-ended stylet.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951401
Not in Commercial Distribution
- 10381780034285 ()
- M2729514011 ()
- 25cm Length x 2.7mm O.D. x 1.4mm I.D. (F8)
951401
- Intracerebral infusion/drainage catheter, long-term
The Subdural Drainage Catheter is a radiopaque, silicone elastomer, drainage catheter consisting of a F8 tubing with a flattened, hollow cage at the distal tip. The Subdural Catheter is provided with 1 Introducing Rod, 1 Luer-lock Connector, 1 Right Angle Guide and 1 Butterfly Suture Clamp
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951315
Not in Commercial Distribution
- 10381780034278 ()
- M2729513151 ()
- 20cm Length x 2.7mm O.D. x 1.2mm I.D. (F8), 37 cm Introducing Rod
951315
- Intracerebral infusion/drainage catheter, long-term
The Subdural Drainage Catheter is a radiopaque, silicone elastomer, drainage catheter consisting of a F8 tubing with a flattened, hollow cage at the distal tip. The Kit contains: 1 Subdural Catheter, 1 Introducing Rod, 1 Luer-lock Connector, 1 Right Angle Guide, 1 Butterfly Suture Clamp, 1 Subcutaneous Passer, 1 Disposable Drill Bit (5 mm) with adjustable stop and 1 Allen Wrench
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951310
Not in Commercial Distribution
- 10381780034261 ()
- M2729513101 ()
- 20cm Length x 2.7mm O.D. x 1.2mm I.D. (F8), 37cm Introducing Rod
951310
- Intracerebral infusion/drainage catheter, long-term
Ventricular Catheter Accessory Kit: 35 cm Radiopaque Straight Ventricular Catheter with large holes and graphite length marks at 5, 10, 15 cm from the tip.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951303
Not in Commercial Distribution
- 10381780034254 ()
- M2729513031 ()
- Vent. Cath. 35cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Introducers 22cm and 37cm Length
951303
- Intracerebral infusion/drainage catheter, short-term
Ventricular Catheters are provided Straight, Finned or Right Angle (inner diameter 1.4mm, outer diameter 2.7mm). They are delivered with an Introducer. Marked Ventricular Catheters feature radiopaque Length Markings at 2.0 cm Intervals from the Tip. A Straight or Right Angle Connector, and/or a silicone Right Angle Guide, are supplied as Accessories. Implanted materials are silicone elastomer with or without barium sulfate, stainless steel, polypropylene with barium sulfate and tantalum.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951102
Not in Commercial Distribution
- 10381780034230 ()
- M2729511021 ()
- 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8)
951102
- Intracerebral infusion/drainage catheter, long-term
Ventricular Catheters are provided Straight, Finned or Right Angle (inner diameter 1.4mm, outer diameter 2.7mm). They are delivered with an Introducer. Marked Ventricular Catheters feature radiopaque Length Markings at 2.0 cm Intervals from the Tip. A Straight or Right Angle Connector, and/or a silicone Right Angle Guide, are supplied as Accessories. Implanted materials are silicone elastomer with or without barium sulfate, stainless steel, polypropylene with barium sulfate and tantalum.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
951101
Not in Commercial Distribution
- 10381780034223 ()
- M2729511011 ()
- 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8)
951101
- Intracerebral infusion/drainage catheter, long-term
49 Cu. Ft. High-Performance Laboratory, Solid Door, Stainless Steel, Blood Bank Freezer. Features an intelligent microprocessor controller with a digital display. Preset to the ideal temperature of -25°C with a standard temperature range of -10°C to -30°C. Environmentally friendly, natural refrigerants are fully compliant with new EPA/SNAP/UL regulations. The K249SDF-SS-BB is Approved as a Class II Medical device and is manufactured under the highest quality standards: ISO 13485 – 2016.
K2 Scientific, LLC
K249SDFSSBB
In Commercial Distribution
- G136K249SDFSSBB0 ()
K249SDF-SS-BB
- Blood refrigerator/freezer
49 Cu. Ft. High-Performance Laboratory, Solid Door, Blood Bank Freezer. Features an intelligent microprocessor controller with a digital display. Preset to the ideal temperature of -25°C with a standard temperature range of -10°C to -30°C. Environmentally friendly, natural refrigerants are fully compliant with new EPA/SNAP/UL regulations. The K249SDF-BB is Approved as a Class II Medical device and is manufactured under the highest quality standards: ISO 13485 – 2016.
K2 Scientific, LLC
K249SDFBB
In Commercial Distribution
- G136K249SDFBB0 ()
K249SDF-BB
- Blood refrigerator/freezer