SEARCH RESULTS FOR: (*Fake Texas A*)(9459 results)
INTENDED USE
For the detection and semi-quantitation of IgG anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.
SUMMARY AND EXPLANATION OF THE I TEST
Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgG anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.
PRINCIPLE OF THE TEST
The test is s an indirect ELISA. Diluted serum/ plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum/plasma proteins by washing, antibodies specific for human IgG, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-β2GPl antibody concentrations expressed in G units.. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert.
CORGENIX MEDICAL CORPORATION
13370
In Commercial Distribution
- 00855360006175 ()
13370
- Anticardiolipin-B2-glycoprotein I complex antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of IgM anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY OF THE TEST
Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic
phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgM anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgM anti-β2GPl antibody concentrations expressed in M units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert.
CORGENIX MEDICAL CORPORATION
038-001
In Commercial Distribution
- 00855360006168 ()
038-001
- Anticardiolipin-B2-glycoprotein I complex antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of IgG anti-β2GPl antibodies in individuals with systemic lupus
erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.
SUMMARY OF THE TEST
Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgG anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgG, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-β2GPl antibody concentrations expressed in G units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert.
CORGENIX MEDICAL CORPORATION
037-001
In Commercial Distribution
- 00855360006151 ()
037-001
- Anticardiolipin-B2-glycoprotein I complex antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of IgA anti-β2GPl antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Use Only.
SUMMARY OF THE TEST
Anti-phospholipid antibodies are a heterogeneous group of immunoglobulins that bind to several anionic phospholipids, including cardiolipin and phosphatidylserine. High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. Patients with positive reactions to both anti-phospholipid and anti-β2GPl assays were more likely to have clinical complications than those positive for only one. Higher prevalence and mean serum levels of IgA anti-β2GPl antibodies have been reported in autoimmune patients. In addition, anti-β2GPl antibodies in SLE patients correlated with clinical manifestations of anti-phospholipid syndrome.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in microwells coated with purified human β2GPl. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgA, labeled with horseradish peroxidase (HRP), are added forming complexes with the β2GPl bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-β2GPl antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided, with the IgA anti-β2GPl antibody concentrations expressed in A units. Controls and patient results are determined from the calibration curve. Refer to Product Package Insert.
CORGENIX MEDICAL CORPORATION
039-001
In Commercial Distribution
- 00855360006144 ()
039-001
- Anticardiolipin-B2-glycoprotein I complex antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY AND EXPLANATION OF THE TEST
Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After the removal of unbound serum proteins by washing, antibodies specific for human IgA labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgA aCL antibodies.
Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgA aCL concentration expressed in APL units. Control and patient results are determined from the calibration curve. Refer to Package Insert.
CORGENIX MEDICAL CORPORATION
13530
In Commercial Distribution
- 00855360006083 ()
13530
- Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY AND EXPLANATION OF THE TEST
Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After removal of unbound serum proteins by washing, antibodies specific for human IgM labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of aCL antibodies. Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgM aCL concentrations expressed in MPL units. One MPL unit is equivalent to 1 μg/mL of an affinity purified standard IgM sample. Control and patient results are determined from the calibration curve. Refer to Package Insert.
CORGENIX MEDICAL CORPORATION
13529
In Commercial Distribution
- 00855360006076 ()
13529
- Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY AND EXPLANATION OF THE TEST
Anti-phospholipid antibodies are auto antibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After removal of unbound serum proteins by washing, antibodies specific for human IgG labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of aCL antibodies.
Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgG aCL concentrations expressed in GPL units. One GPL unit is equivalent to 1 μg/mL of an affinity purified standard IgG sample. Control and patient results are determined from the calibration curve. Refer to Package Insert.
CORGENIX MEDICAL CORPORATION
13525
In Commercial Distribution
- 00855360006069 ()
13525
- Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY AND EXPLANATION OF THE IGA TEST
Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After removal of unbound serum proteins by washing, antibodies specific for human IgA labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgA aCL antibodies.
Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgA aCL concentration expressed in APL units. The O.D. values of the controls and patient samples are multiplied by the conversion factor to obtain IgA aCL values, expressed in APL units. Control and patient results are determined from the calibration curve. Refer to Package Insert.
CORGENIX MEDICAL CORPORATION
026-001
In Commercial Distribution
- 00855360006052 ()
026-001
- Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)
INTENDED USE
For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.
SUMMARY AND EXPLANATION OF THE TEST
Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations.
PRINCIPLE OF THE TEST
The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After the removal of unbound serum proteins by washing, antibodies specific for human IgG or IgM labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of aCL antibodies. Results are obtained by reading the O.D. of each test well with a spectrophotometer. Calibrator sera are provided, with the IgG and IgM aCL concentrations expressed in GPL or MPL units, respectively. The O.D. values of all the other samples are multiplied by the conversion factors to obtain IgG and IgM aCL antibody concentrations in standard units. Control and patient results are determined from the calibration curve. Refer to Product Product Insert.
CORGENIX MEDICAL CORPORATION
023-001
In Commercial Distribution
- 00855360006045 ()
023-001
- Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)
ARK™ EDDP Control is intended for use in quality control of the ARK™ EDDP Assay.
ARK DIAGNOSTICS INC
5051-0003-01
In Commercial Distribution
- 00858724003926 ()
5051-0003-01
- 2-ethylidine-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) IVD, control