SEARCH RESULTS FOR: (*bitcoin mining hardware comparison馃挷itenthusiasts.com馃挷Cryptocurrency*)(6385 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

5 cables in one bag with 10 pin yoked jumper cables yellow to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-019-005
In Commercial Distribution

  • 00856750007130 ()
PE-002-019-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables black to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-017-005
In Commercial Distribution

  • 00856750007116 ()
PE-002-017-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables black to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-014-005
In Commercial Distribution

  • 00856750007109 ()
PE-002-014-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables red to split ECG signals between two ECG devices is an accessory to the PURE EP System The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-013-005
In Commercial Distribution

  • 00856750007093 ()
PE-002-013-005

  • Cardiac electrophysiology analysis system
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-30P
In Commercial Distribution

  • 00858418003836 ()
CemO-30P

  • Bone matrix implant, synthetic, non-antimicrobial
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-20P
In Commercial Distribution

  • 00858418003287 ()
CemO-20P

  • Bone matrix implant, synthetic, non-antimicrobial
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-02P
In Commercial Distribution

  • 00858418003263 ()
CemO-02P

  • Bone matrix implant, synthetic, non-antimicrobial
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-05P
In Commercial Distribution

  • 00858418003027 ()
CemO-05P

  • Bone matrix implant, synthetic, non-antimicrobial
The NeuroSync EYE-SYNC device is a portable, fully enclosed eye tracking environment with two primary components: 1. Eye Tracker (head-mounted device) with eye tracking sensor and display 2. Android Tablet The eye tracker is a Pico Neo 3 Pro Eye with embedded sensors provided by Tobii Tech. It is mounted to the subject's face and held in place using a strap. The eye tracking sensor includes two cameras (one for each eye) to capture eye movement data. Eye gaze tracking is performed using a proprietary implementation of the pupil-corneal reaction method. The integrated display within the headset provides a binocular visual field and operates as part of the standalone VR system, running on Qualcomm Snapdragon XR2 hardware. The headset processes eye-tracking data internally and supports USB-C connectivity. The display receives eye tracking sensor information for post-processing, manages sensor calibration, provides binocular visual display to the subject, and interfaces with the Android tablet over Bluetooth. Eye gaze tracking and visual display is combined to provide several assessment paradigms to characterize subject eye tracking performance.
NEUROSYNC INC.
X03
In Commercial Distribution

  • 00860013612900 ()


  • Vision physiology/eye movement analysis system
  • Eye-tracking neurological/brain injury assessment device
Noromed computerized manual muscle testing offers manual muscle testing at its best by bringing science to what once was an art. The muscle testing hardware includes an ergonomic force gauge and five attachments to choose from which provide easy, comfortable testing of all muscle groups - large and small. Now you can perform real time strength testing - quickly and easily - and all fully documented by the computer interface. The flexibility of the system allows you to use pre-programmed established protocols or create your own. Designed to meet your needs, the software calculates the statistics appropriate to each test as well as generating a wide variety of documentation to fit your specific needs. This documentation includes: Supportive documentation reports which contain the graphic reports and profiles of the actual test data. Reports included are: •A composite report of individual test results by protocol and muscles tested as well as calculated deficits. •A test comparison report which collects and displays the patient's historical results. •A Myotest data report which presents both statistical data and graphical data of the individual test broken down by trial.
MYOTRONICS NOROMED, INC
Muscle Tester
In Commercial Distribution

  • D792N9600A0 ()


  • Virtual-display rehabilitation system, non-supportive, clinical
< 1 ... 631 632 633 634 635 ... 639 >