SEARCH RESULTS FOR: 太阳城集团注册送20→→1946.cc←←太阳城集团注册送20.zjmd(40116 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
SCREW 55811014520 CNSAS 4.5 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811014520
In Commercial Distribution
- 00643169065413 ()
- Outer Diameter: 4.5 Millimeter
- Length: 20.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811015520 CNSAS 5.5 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811015520
In Commercial Distribution
- 00643169065222 ()
- Outer Diameter: 5.5 Millimeter
- Length: 20.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811019020 CNSAS 9.0 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811019020
In Commercial Distribution
- 00643169065093 ()
- Length: 20.0 Millimeter
- Outer Diameter: 9.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811019520 CNSAS 9.5 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811019520
In Commercial Distribution
- 00643169064812 ()
- Outer Diameter: 9.5 Millimeter
- Length: 20.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811017520 CNSAS 7.5 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811017520
In Commercial Distribution
- 00643169064614 ()
- Outer Diameter: 7.5 Millimeter
- Length: 20.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811018520 CNSAS 8.5 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811018520
In Commercial Distribution
- 00643169064492 ()
- Outer Diameter: 8.5 Millimeter
- Length: 20.0 Millimeter
- Spinal bone screw, non-bioabsorbable
SCREW 55811018020 CNSAS 8.0 X 20 CC
MEDTRONIC SOFAMOR DANEK, INC.
55811018020
In Commercial Distribution
- 00643169064331 ()
- Length: 20.0 Millimeter
- Outer Diameter: 8.0 Millimeter
- Spinal bone screw, non-bioabsorbable
The reusable BE 30-142 is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%.
Objectives of PEEP therapy:
1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,
2) aid in the prevention of atelectasis via aveolar stinting,
3) decrease in the inspired oxygen fraction (FiO2) is an advantage,
4) help in the stabilization of flail chest condition, and
5) monitor tidal volume by connecting a spirometer to the outlet port.
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 30-142
In Commercial Distribution
- M996BE301420 ()
- PEEP valve, reusable
The reusable BE 142-A is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%.
Objectives of PEEP therapy:
1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,
2) aid in the prevention of atelectasis via aveolar stinting,
3) decrease in the inspired oxygen fraction (FiO2) is an advantage,
4) help in the stabilization of flail chest condition, and
5) monitor tidal volume by connecting a spirometer to the outlet port.
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 142-A
In Commercial Distribution
- M996BE142A0 ()
- PEEP valve, reusable
The reusable BE 142 is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%.
Objectives of PEEP therapy:
1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,
2) aid in the prevention of atelectasis via aveolar stinting,
3) decrease in the inspired oxygen fraction (FiO2) is an advantage,
4) help in the stabilization of flail chest condition, and
5) monitor tidal volume by connecting a spirometer to the outlet port.
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 142
In Commercial Distribution
- M996BE1420 ()
- PEEP valve, reusable