SEARCH RESULTS FOR: ablation(30421 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

CATH 076586 RFMARINR 5F SCXXL W/O CE
MEDTRONIC, INC.
076586
In Commercial Distribution

  • 00763000227630 ()

  • Electrode spacing 2.5.2 mm
  • Catheter deflectable tip length 65 mm
  • Catheter usable length 80 cm
  • Catheter distal electrode size 4 mm
  • Catheter size 1.7mm (5 Fr)


  • Cardiac radio-frequency ablation system catheter
CATH 076585 RF MARINR 5F SCXL W/O CE
MEDTRONIC, INC.
076585
In Commercial Distribution

  • 00763000227647 ()

  • Catheter distal electrode size 4 mm
  • Catheter deflectable tip length 55 mm
  • Catheter size 1.7mm (5 Fr)
  • Electrode spacing 2.5.2 mm
  • Catheter usable length 80 cm


  • Cardiac radio-frequency ablation system catheter
CATH 075802 RF MARINR W/O CE
MEDTRONIC, INC.
075802
In Commercial Distribution

  • 00763000227623 ()

  • Catheter distal electrode size 4 mm
  • Catheter deflectable tip length 40-60 mm
  • Catheter size 2.3mm (7 Fr)
  • Electrode spacing 2.2.250 mm
  • Catheter usable length 110 cm


  • Cardiac radio-frequency ablation system catheter
The NovaSure® Impedance Controlled Endometrial Ablation System is intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia (excessive bleeding) due to benign causes for whom childbearing is complete.
Hologic, Inc.
NS2000US
In Commercial Distribution

  • 15420045501140 ()
  • 25420045501147 ()
  • 35420045501144 ()
NS2000US

  • Radio-frequency endometrial-ablation system handpiece/electrode
The NovaSure® Impedance Controlled Endometrial Ablation System is intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia (excessive bleeding) due to benign causes for whom childbearing is complete.
Hologic, Inc.
2007
In Commercial Distribution

  • 15420045501133 ()
  • 25420045501130 ()
  • 35420045501137 ()
  • 45420045501134 ()
NS2007US

  • Radio-frequency endometrial-ablation system handpiece/electrode
The NovaSure® Impedance Controlled Endometrial Ablation System is intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia (excessive bleeding) due to benign causes for whom childbearing is complete.
Hologic, Inc.
2013
In Commercial Distribution

  • 15420045501126 ()
  • 35420045501120 ()
  • 25420045501123 ()
  • 45420045501127 ()
NS2013KITUS

  • Radio-frequency endometrial-ablation system handpiece/electrode
The NovaSure® Impedance Controlled Endometrial Ablation System is intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia (excessive bleeding) due to benign causes for whom childbearing is complete.
Hologic, Inc.
NS2013US
In Commercial Distribution

  • 15420045501119 ()
  • 25420045501116 ()
  • 35420045501113 ()
  • 45420045501110 ()
NS2013US

  • Radio-frequency endometrial-ablation system handpiece/electrode
The NovaSure®Impedance Controlled Endometrial Ablation System is intended to ablate the endometrial lining of the uterus in pre-menopausal women with menorrhagia (excessive bleeding) due to benign causes for whom childbearing is complete.
Hologic, Inc.
NovaSure Controller
In Commercial Distribution

  • 15420045500860 ()
RFC2010-115

  • Radio-frequency endometrial-ablation system generator
No Description
Hologic, Inc.
NovaSure Controller
In Commercial Distribution

  • 15420045500853 ()


  • Tumour-therapy radio-frequency hyperthermia system
WRENCH 1036W 1 1/8 FOR CRYOCONSOLE MDR
MEDTRONIC, INC.
1036W
In Commercial Distribution

  • 00763000306656 ()


  • Cardiac cryosurgical system
< 1 ... 152 153 154 155 156 ... 1000 >