SEARCH RESULTS FOR: 网赚短信通道产品(唯一TG:ppo995)全球短信群发106三网国际通道.muv(14852 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
The DEKA SmartXide2 Trio is a medical laser system equipped with a 80W CO2 laser source and an (optional) 980nm or 940nm 50W diode laser source.
EL.EN. SPA
M103AF1
In Commercial Distribution
- 08057017760399 ()
M103AF1
- General/multiple surgical solid-state/carbon dioxide laser system
The Minisilk-FT is a pulsed light system having a Xenon flashlamp located in the handpieces. It is a light source emitting in the wavelength range 500-1200nm.
Emission activation is by footswitch. Overall weight of the system is 16kg, and the size is 22x37x45cm (HxWxD).
Electrical requirement is: 115 VAC, 10A, 50-60 Hz, single phase.
EL.EN. SPA
M081R1
In Commercial Distribution
- 08057017760337 ()
M081R1
- Multi-modality skin contouring system
The smartxide Touch system consists in a carbon dioxide laser (CO2) with 60W of maximum power. The CO2 laser radiation is delivered to the treatment area through the handpieces or the scanning units.
EL.EN. SPA
M110H1
In Commercial Distribution
- 08057017760313 ()
M110H1
- General/multiple surgical carbon dioxide laser system
The Smartxide Tetra system consists in a carbon dioxide laser (CO2) with 50W of maximum power. The CO2 laser radiation is delivered to the treatment area through the handpieces or the scanning units.
EL.EN. SPA
M118D1
In Commercial Distribution
- 08057017760306 ()
M118D1
- General/multiple surgical carbon dioxide laser system
The SmartXide2 system consists in a 10,600nm carbon dioxide laser (CO2) laser with 80W of maximum power. It can be equipped with an optional diode laser source of 50W maximum power. The laser radiation is delivered to the treatment area through the handpieces or the scanning units. A wide range of handpieces can be provided with the SmartXide² system, having different spot sizes and high performances in specific application field.
EL.EN. SPA
M103AB1
In Commercial Distribution
- 08057017760276 ()
M103AB1
- General/multiple surgical diode/carbon dioxide laser system
DEKA SmartXide UltraSpeed is a 10,600 nm CO2 laser devices whit a maximum power of 40W.
The laser source delivers the laser output through interchangeable laser handpieces.
Handpiece activation is by footswitch.
EL.EN. SPA
M110G1
In Commercial Distribution
- 08057017760245 ()
M110G1
- Dental carbon dioxide laser system
The DEKA Motus AX is a medical device equipped with a 755nm solid state laser source.
The laser source delivers the laser output through a lens coupled user replaceable optical fiber with a wide range of interchangeable, quick release laser handpieces with electronic spot recognition.
Handpiece activation is either by footswitch or fingerswitch.
EL.EN. SPA
M112B1
In Commercial Distribution
- 08057017760221 ()
M112B1
- Dermatological solid-state laser system
The ASA LASER HIRO 3.0 device is a medical device for carrying out therapy in the treatment of musculotendinous and joint pathologies with Nd:YAG Laser source.
EL.EN. SPA
M080K1
In Commercial Distribution
- 08057017760214 ()
M080K1
- Musculoskeletal infrared phototherapy unit, non-wearable
The ASA LASER SH1 device is a medical device for carrying out therapy in the treatment of musculotendinous and joint pathologies with Nd:YAG laser sources.
EL.EN. SPA
M077H3
In Commercial Distribution
- 08057017760207 ()
M077H3
- Musculoskeletal infrared phototherapy unit, non-wearable
The SmartXide Touch system consists in a carbon dioxide laser (CO2) with 60W of maximum power. The CO2 laser radiation is delivered to the treatment area through the handpieces or the scanning units.
EL.EN. SPA
M110C1
In Commercial Distribution
- 08057017760153 ()
M110C1
- Dermatological carbon dioxide laser system
The SmartXide² system consists in a carbon dioxide laser (CO2) laser with 60W of maximum power. The CO2 laser radiation is delivered to the treatment area through the handpieces or the scanning units. A wide range of handpieces can be provided with the Smartxide² system, having different spot sizes and high performances in specific application field.
EL.EN. SPA
M103P1
In Commercial Distribution
- 08057017760146 ()
M103P1
- Dermatological carbon dioxide laser system
The Cynosure Smartskin+ system consists in a carbon dioxide laser (CO2) with 30W of maximum power. The CO2 laser radiation is delivered to the treatment area through an handpiece or a scanning unit.
EL.EN. SPA
M079AZ1
In Commercial Distribution
- 08057017760139 ()
M079AZ1
- Dermatological carbon dioxide laser system
The Synchro Repla:y Premium 1.4.2 is a medical laser workstation equipped with an High power Alexandrite 755 nm laser. The system can also be equipped with a pulsed light handpieces.
EL.EN. SPA
M104J1
In Commercial Distribution
- 08057017760122 ()
M104J1
- Multi-modality skin surface treatment system
The Synchro Repla:y Excellium HP is a medical laser workstation equipped with an high power Nd:YAG 1064 nm laser. The system can also be equipped with a pulsed light handpieces.
EL.EN. SPA
M104L1
In Commercial Distribution
- 08057017760115 ()
M104L1
- Multi-modality skin surface treatment system
The Synchro Repla:y Excellium 3.4 is a medical laser workstation equipped with an High power Alexandrite 755 nm laser and an high power Nd:YAG 1064 nm laser. The system can also be equipped with a pulsed light handpieces.
EL.EN. SPA
M104K1
In Commercial Distribution
- 08057017760108 ()
M104K1
- Multi-modality skin surface treatment system
The smart US-20D system consists in a carbon dioxide laser (CO2) with 25W of maximum power. The CO2 laser radiation is delivered to the treatment area through handpieces or a scanning unit (DOT scanner).
EL.EN. SPA
M079B1
In Commercial Distribution
- 08057017760092 ()
M079B1
- Dermatological carbon dioxide laser system
The Smartxide 50 system consists in a carbon dioxide laser (CO2) with 50W of maximum power. The CO2 laser radiation is delivered to the treatment area through handpieces or a scanning unit (DOT scanner).
EL.EN. SPA
M079AL1
In Commercial Distribution
- 08057017760085 ()
M079AL1
- Dermatological carbon dioxide laser system
The Smartxide system consists in a carbon dioxide laser (CO2) with 30W of maximum power. The CO2 laser radiation is delivered to the treatment area through handpieces or a scanning unit (DOT scanner).
EL.EN. SPA
M079R1
In Commercial Distribution
- 08057017760078 ()
M079R1
- Dermatological carbon dioxide laser system
The Smartfile medical system is a Nd:YAG laser device for treatment of dental desease. The laser radiation is delivered to the treatment area through the handpieces.
EL.EN. SPA
M077C2
Not in Commercial Distribution
- 08057017760054 ()
M077C2
- Dental solid-state laser system
The Cynosure SLT II workstation has a solid state Nd:YAG laser capable of emitting laser radiation in three wavelenghts and includes a wide range of different delivery system, handpieces, fibers, cannulas and other accessories.
EL.EN. SPA
M094E1
In Commercial Distribution
- 08057017760009 ()
M094E1
- General/multiple surgical solid-state laser system
12‐lead high‐performance, multi‐channel, interpretative resting electrocardiograph which displays, acquires, prints and stores ECG tracings for adults and children. 4.3" display and 100mm printer paper.
CARDIOLINE SPA
ECG100+
In Commercial Distribution
- 08056732653610 ()
80508095
- Electrocardiograph, professional, multichannel
Digital portable acquisition device which can acquire the electrocardiographic signal of 12 standard leads. Connected with a receiver via Bluetooth or USB, sends the data to the host.
CARDIOLINE SPA
HD+12
In Commercial Distribution
- 08056732652422 ()
81018331
- Electrocardiograph, professional, multichannel
No Description
IDEA HEALTH LLC
ID-WS809
In Commercial Distribution
- G057IDWS8091 ()
- G057IDWS8090 ()
- G057IDWS8092 ()
- Stand-on floor scale, electronic
The Zeto ONE Head Unit is a detachable part of the Zeto ONE, which is an EEG system intended for prescription use in healthcare facility, home, and specific transport environments to acquire, transmit, display and store EEG and auxiliary signals for adults and children, not including newborns.
The Head Unit component of the Zeto ONE is intended to hold electrodes on the subject's scalp and aquire electric signals produced by human brain activity.
ZETO INC
ZP-120-11011
In Commercial Distribution
- B675ONEHU1 ()
- Regular
- Small
- Electroencephalograph
G.o.c.c.l.e.s light represents the proprietary light source to be used with G.o.c.c.l.e.s eyewear in order to allow the illumination of the oral cavity during oral examination, characterized by an excitation band from 440 to 490 nm.
PIERREL SPA
G.o.c.c.l.e.s. light
In Commercial Distribution
- 08051040582010 ()
531000611
- Oral lesion examination light
The MOTUS PRO AX is a medical laser equipped with Alexandrite 755nm laser only.
The laser sources deliver the laser output through a lens coupled user replaceable optical fiber with a wide range of interchangeable, quick release laser handpieces with electronic spot recognition.
DEKA M.E.L.A. SRL
M130P1
In Commercial Distribution
- 08034108512907 ()
- Multi-modality skin surface treatment system
The MOTUS PRO is a medical laser equipped with Alexandrite 755nm laser and Nd:YAG 1064nm laser.
The laser sources deliver the laser output through a lens coupled user replaceable optical fiber with a wide range of interchangeable, quick release laser handpieces with electronic spot recognition.
DEKA M.E.L.A. SRL
M130N1
In Commercial Distribution
- 08034108512891 ()
- Multi-modality skin surface treatment system
The SMARTXIDE TETRA PRO DEVICE consists of a 10,600nm carbon dioxide laser (CO2) laser with 40W of maximum power. The laser energy is delivered to the treatment area via an articulated arm and a delivery accessory connected to its distal end. The articulated arm is an optical assembly that delivers free beam laser radiation. It is made up of seven mirrors placed on rotating knuckles: the mechanical accuracy of the articulated arm allows the CO2 laser beam to travel inside it and along its axis regardless of the arm orientation. The device may be used in combination with scanning units in order to achieve greater predictability and reproducibility. The use with the scanning units is indicated for layer-by-layer char-free ablation, enhancing the safety of the treatment with more uniform, accurate and controllable impact such as ablative skin resurfacing.
DEKA M.E.L.A. SRL
M118G1
In Commercial Distribution
- 08034108512808 ()
- General/multiple surgical carbon dioxide laser system
The SmartXide PRO is a medical device indicated for incision, excision, ablation, vaporization and coagulation of body soft tissues incluing intraoral tissues, in medical specialties including aesthetic (dermatology and plastic surgery), otolaryngology (ENT), gynaecology, neurosurgery, dental and oral surgery and genitourinary surgery. The use with the scanning unit is indicated for ablative skin resurfacing.
DEKA M.E.L.A. SRL
M079BI1
In Commercial Distribution
- 08034108512709 ()
M079R1
- Dermatological carbon dioxide laser system
The Elite iQ PRO Laser System is indicated fot stable long-term or permanent hair reduction. Peramanent hair reduction is defined as long-term stable reduction in the number of hairs regrowing when measured at 6, 9 or 12 months after the completiomn of a treatment regime. It is used for skin types (Fitzpatrick I-VI) including tanned skin. It is also indicated for the treatment of vascular lesions, benign pigmented lesions, and wrinkles.
1064nm:
The Elite iQ PRO Laser System is intended for the coagulation and hemostasis of benign vascular lesions such as, but not limited to, port wine stains, hemangiomas, warts, telangiectasia, rosacea, venous lakes, leg veins, spider wine and poikiloderma of Civatte; and treatment of benign cutaneous lesions such as, but not limited to, lentigines (age spots), solar lentigines (sunspots), cafe au lait macules, seborrheic keratoses, nevi, chloasma, verrucae, skin tags, keratosis and plaques.
The laser is also indicated for the treatment of wrinkles such as, but not limited to, periocular and perioral wrinkles.
Additionally, the laser is indicated for the treatment of psuedo folliculitis barbae (PFB) and for stable long-term or permanent hair reduction. Permanent hair reduction is defined as long-term stable reduction in the number of hairs regrowing when measured at 6,9 and 12 months after the competition of a treatment regime.
The Skintel Reader is intended as an onbjective measurement tool for examing skin melanin content for determing and setting a test spot starting fluence.
DEKA M.E.L.A. SRL
M122K1
In Commercial Distribution
- 08034108512655 ()
M122K1
- Multi-modality skin surface treatment system
The DEKA AGAIN PRO family is a medical laser family equipped with Nd:YAG 1064nm laser.
The laser sources deliver the laser output through a lens coupled user repleaceable optical fiber with a wider range of intercheangeable, quick release laser handpieces with electronic spot recognition.
DEKA M.E.L.A. SRL
M126AB1
In Commercial Distribution
- 08034108512532 ()
- Multi-modality skin surface treatment system
The DEKA AGAIN PRO family is a medical laser family equipped with Alexandrite 755nm laser and Nd:YAG 1064nm laser.
The laser sources deliver the laser output through a lens coupled user repleaceable optical fiber with a wider range of intercheangeable, quick release laser handpieces with electronic spot recognition.
DEKA M.E.L.A. SRL
M126AA1
In Commercial Distribution
- 08034108512525 ()
- Multi-modality skin surface treatment system
ATTIVA is a Radiofrequency (RF) System (generator, electrodes/handpieces and accessories) indicated for treatments based on the emission of electromagnetic waves that lead to a rise of internal temperature of tissues involved in the treatment for electrocoagulation and hemostasis. ATTIVA device can be used on adult patients only.
It comprises of a base unit, activation pedal, ground pad (K203494), endodermic handpiece, thermal camera (K033967) and monitor, and blunt cannulas and RF electrodes.
ITALIAN ENGINEERING SRL
MD01
In Commercial Distribution
- 08055510890087 ()
- Weight: 5.8 Kilogram
- Length: 38.5 Centimeter
- Height: 10 Centimeter
- Width: 20.5 Centimeter
- Percutaneous radio-frequency ablation system generator
Imaging System
LIGHTLAB IMAGING, INC.
900-700-00
In Commercial Distribution
- 00183739000630 ()
900-700-00
- Coronary optical coherence tomography system
Breast Grid (User-Sterilized)
Philips Medical Systems Nederland B.V.
989603214224
In Commercial Distribution
- 00884838120211 ()
- 00884838118799 ()
- Needle guide, single-use
The Incisive CT is a Computed Tomography X-Ray System intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes. This device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Philips Healthcare (Suzhou) Co., Ltd.
728144
In Commercial Distribution
- 00884838105508 ()
728144
- Full-body CT system
The DuraDiagnost is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. This device is not intended for mammographic applications.
Philips Healthcare (Suzhou) Co., Ltd.
712214
Not in Commercial Distribution
- 00884838064751 ()
712214
- Stationary basic diagnostic x-ray system, digital
The DuraDiagnost Compact is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. This device is not intended for mammographic applications.
Philips Healthcare (Suzhou) Co., Ltd.
989701001012
Not in Commercial Distribution
- 00884838064737 ()
712213
- Stationary basic diagnostic x-ray system, digital
Biopsy Grid (User-sterilized)
Philips Ds North America LLC
98960321422
In Commercial Distribution
- 00884838083615 ()
- MRI system coil, radio-frequency
Biopsy Grid
Philips Ds North America LLC
98960321420
In Commercial Distribution
- 00884838083608 ()
- MRI system coil, radio-frequency
The DigitalDiagnost C50 is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. This device is not intended for mammographic applications.
Philips Healthcare (Suzhou) Co., Ltd.
712201
Not in Commercial Distribution
- 00884838082366 ()
712201
- Stationary basic diagnostic x-ray system, digital
Stationary x-ray system
Philips Healthcare (Suzhou) Co., Ltd.
712203
In Commercial Distribution
- 00884838095205 ()
- Stationary basic diagnostic x-ray system, digital
Stationary x-ray system
Philips Healthcare (Suzhou) Co., Ltd.
712204
In Commercial Distribution
- 00884838095199 ()
- Stationary basic diagnostic x-ray system, digital
The CT 5300 is a Computed Tomography X-Ray System is intended to produce images of the head and body by computer reconstruction of X-Ray transmission data taken at different angles and planes. This device includes data acquisition system, detection management system and an operating console with display monitors along with patient and system supporting devices, accessories and components.
Philips Healthcare (Suzhou) Co., Ltd.
728285
In Commercial Distribution
- 00884838113237 ()
728285
- Full-body CT system
OHDII FHD QL AIR05
MAQUET SAS
ARD568803969
In Commercial Distribution
- 03700712434298 ()
- Surgical video camera
Electronic unit for identifying the localised haemorrhoidal arteries by means of acoustic signals. Part of the A.M.I. HAL/RAR System.
The A.M.I. HAL-II Electronic System is a Doppler-based device. It is powered by a DC voltage source (rechargeable batteries or 12 V adapter). The A.M.I. HAL-II Electronic System generates electrical signals, calculates differences between the wavelength of outgoing and reflected electrical signals, and generates an acoustic Doppler signal.
Together with auxiliary A.M.I. devices (A.M.I. HAL Handle, Probe and Sleeve) the A.M.I. HAL-II Electronic System serves for the detection of haemorrhoidal arteries and enables manual ligation of detected arteries, as well as mucopexy of prolapsing haemorrhoidal mucosa.
AMI Agency for Medical Innovations GmbH
AHE 203
Not in Commercial Distribution
- EAMIAHE2030 ()
- Weight: 3.2 Kilogram
- Depth: 260 Millimeter
- Height: 140 Millimeter
- Width: 385 Millimeter
AHE 203
- Noninvasive vascular ultrasound system
No Description
TELEFLEX INCORPORATED
IPN924894
In Commercial Distribution
- 24026704741834 ()
- 14026704741837 ()
- Weight: 15.8 Pound
- Width: 14 Inch
- Height: 5.5 Inch
- Length: 12 Inch
528300PS
- General-purpose light source
No Description
PAR Medizintechnik GmbH & Co. Kommanditgesellschaft
2001589-232
In Commercial Distribution
- 04260671372202 ()
- Length: 405 Millimeter
- Width: 115 Millimeter
- Blood pressure cuff, single-use
Gastroscope
Ambu A/S
582101000
In Commercial Distribution
- 05707480161867 ()
- 05707480161850 ()
- Outer Diameter: 12 Millimeter
- Lumen/Inner Diameter: 4.2 Millimeter
- Length: 103 Centimeter
582101000
- Flexible video gastroscope, single-use
NeoNavia FlexiPulse probe
NeoDynamics AB (publ)
2104
Not in Commercial Distribution
- 27350081940076 ()
- 17350081940079 ()
- 37350081940073 ()
- Needle Gauge: 14 Gauge
2104
- End-cut biopsy gun needle