SEARCH RESULTS FOR: (*cryptocurrency exchange hong kong馃挷itenthusiasts.com馃挷Enthusiasts*)(31082 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Single Use Medical Device for Ophthalmic Surgery
Bausch & Lomb GmbH
SUJ02
In Commercial Distribution

  • 24058935005461 ()
  • 04058935005467 ()
SUJ02

  • Vitrectomy fluid/gas handling handpiece/cannula
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 6.0mm, Length = 150mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LA18-05060150
In Commercial Distribution

  • 04543660026530 ()
LA18-05060150

  • Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 6.0mm, Length = 100mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LA18-05060100
In Commercial Distribution

  • 04543660026523 ()
LA18-05060100

  • Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 50cm, Diameter = 5.0mm, Length = 150mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LA18-05050150
In Commercial Distribution

  • 04543660026516 ()
LA18-05050150

  • Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 6.0mm, Length = 100mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14560100
In Commercial Distribution

  • 04543660026462 ()
LW18-14560100

  • Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 5.0mm, Length = 150mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14550150
In Commercial Distribution

  • 04543660026455 ()
LW18-14550150

  • Peripheral angioplasty balloon catheter, basic
The Aperta NSE PTA is a peripheral cutting/scoring NC balloon with 4 nylon elements to reduce slippage during inflation. Nominal Pressure = 10atm, Rated Burst Pressure = 20atm, Guide Wire Compatibility = 0.018” OTW, Shaft Length = 145cm, Diameter = 5.0mm, Length = 100mm, Minimum Introducer Sheath = 6F. The Aperta NSE PTA Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries, including iliac, femoral, ilio-femoral, popliteal and infra-popliteal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of in-stent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature. This device is not for use in the coronary or neuro-vasculature including carotid arteries.
GOODMAN CO.,LTD.
LW18-14550100
In Commercial Distribution

  • 04543660026448 ()
LW18-14550100

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40040ER
In Commercial Distribution

  • 04540778175013 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 40 mm
  • Balloon Diameter; 4.0 mm
BD-Q40040ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30040ER
In Commercial Distribution

  • 04540778174993 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 40 mm
  • Balloon Diameter; 3.0 mm
BD-Q30040ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25040ER
In Commercial Distribution

  • 04540778174979 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 40 mm
  • Balloon Diameter; 2.5 mm
BD-Q25040ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20040ER
In Commercial Distribution

  • 04540778174955 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 40 mm
  • Balloon Diameter; 2.0 mm
BD-Q20040ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60020ER
In Commercial Distribution

  • 04540778174931 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 6.0 mm
BD-Q60020ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50020ER
In Commercial Distribution

  • 04540778174917 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 5.0 mm
BD-Q50020ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40020ER
In Commercial Distribution

  • 04540778174894 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 4.0 mm
BD-Q40020ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30020ER
In Commercial Distribution

  • 04540778174870 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 3.0 mm
BD-Q30020ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25020ER
In Commercial Distribution

  • 04540778174856 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.5 mm
BD-Q25020ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20020ER
In Commercial Distribution

  • 04540778174832 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.0 mm
BD-Q20020ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P70200ER
In Commercial Distribution

  • 04540778167155 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 7.0 mm
BD-P70200ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P60200ER
In Commercial Distribution

  • 04540778167131 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 6.0 mm
BD-P60200ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P50200ER
In Commercial Distribution

  • 04540778167117 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 18 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 5.0 mm
BD-P50200ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P40200ER
In Commercial Distribution

  • 04540778167094 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 4.0 mm
BD-P40200ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P30200ER
In Commercial Distribution

  • 04540778167070 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 3.0 mm
BD-P30200ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P70150ER
In Commercial Distribution

  • 04540778167056 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 7.0 mm
BD-P70150ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P60150ER
In Commercial Distribution

  • 04540778167032 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 6.0 mm
BD-P60150ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P50150ER
In Commercial Distribution

  • 04540778167018 ()

  • Balloon Length; 150 mm
  • Balloon Diameter; 5.0 mm
  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 18 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
BD-P50150ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P40150ER
In Commercial Distribution

  • 04540778166998 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 4.0 mm
BD-P40150ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P30150ER
In Commercial Distribution

  • 04540778166974 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 3.0 mm
BD-P30150ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P70120ER
In Commercial Distribution

  • 04540778166950 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 7.0 mm
BD-P70120ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P60120ER
In Commercial Distribution

  • 04540778166936 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 6.0 mm
BD-P60120ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P50120ER
In Commercial Distribution

  • 04540778166912 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 18 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 5.0 mm
BD-P50120ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P40120ER
In Commercial Distribution

  • 04540778166899 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 4.0 mm
BD-P40120ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P30120ER
In Commercial Distribution

  • 04540778166875 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 3.0 mm
BD-P30120ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P70100ER
In Commercial Distribution

  • 04540778166851 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 7.0 mm
BD-P70100ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P60100ER
In Commercial Distribution

  • 04540778166837 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 6.0 mm
BD-P60100ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P50100ER
In Commercial Distribution

  • 04540778166813 ()

  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 18 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 5.0 mm
  • Maximum Guidewire Diameter; 0.035 inch
BD-P50100ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P40100ER
In Commercial Distribution

  • 04540778166790 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 4.0 mm
BD-P40100ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P30100ER
In Commercial Distribution

  • 04540778166776 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 20 atm
  • Nominal Pressure; 10 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 3.0 mm
BD-P30100ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P80080ER
In Commercial Distribution

  • 04540778166752 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 12 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 8.0 mm
BD-P80080ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P70080ER
In Commercial Distribution

  • 04540778166738 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 7.0 mm
BD-P70080ER

  • Peripheral angioplasty balloon catheter, basic
R2P METACROSS RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P METACROSS RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.035 inches (0.89 mm).
KANEKA CORPORATION
BD-P60080ER
In Commercial Distribution

  • 04540778166714 ()

  • Maximum Guidewire Diameter; 0.035 inch
  • Compatible Sheath Diameter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 5.7 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 6.0 mm
BD-P60080ER

  • Peripheral angioplasty balloon catheter, basic
< 1 ... 214 215 216 217 218 ... 250 >