The Emerald Herbst appliance is a customized oral device featuring both lower and upper trays and interlocking system. The product is non-sterile, biocompatible, and provided in a sealed box with instructions for use. The upper and lower trays are connected by an adjustable hinge allowing the patient to open and close the mouth while wearing the appliance. The Herbst Telescopic Hardware on the side of the device allows the patient to move forward and left and right but not backwards. This freedom of movement is important for comfort and overall success of the device. The Emerald Herbst appliance treats snoring and mild to moderate sleep apnea by guiding the mandible forward during sleep, preventing the tongue and soft tissues of the throat from collapsing into the airway.
Island Dental Lab Inc. DBA Emerald Dental Lab
Emerald Herbst
In Commercial Distribution

  • DR3064993 ()


  • Mandible-repositioning/palate-lifting sleep-disordered breathing orthosis
Expression MRI Patient Vital Signs Monitor, Wireless 2.4 GHz Dual Lead ECG Capable, Wireless 2.4 GHz, Pulse Oximetry (SpO2) Capable, Integrated Non-Invasive Blood Pressure (NIBP), Advanced ECG Filter, Integrated End-Tidal CO2, Active Trend Arrows, 360 Degree Alarm light, Quick Connect Accessories, All parameters support Adult, Pediatric, Infant and Neonatal applications, 8-Hour Smart Battery Technology, One (1) year limited warranty and factory service for hardware, Patient Monitor manufactured by Philips Healthcare and branded for Invivo Corporation, anaffiliate of Philips Healthcare. The Patient Monitor is provided with Invivo's standard 1 year. Warranty,a copy of which is available upon request. Post warranty service may be purchased for the Invivo Patient Monitor at the point of sale. For service after the point-of-sale, please contact. Invivo at 1-877-468-4861 option 1, option 3.
Philips Ds North America LLC
Expression MRI Patient Monitor
Not in Commercial Distribution

  • 00884838016064 ()
865214

  • General-purpose multi-parameter bedside monitor
The Chartis Tablet Console is a two-part spirometry system comprised of a touchscreen computer and sensor enclosure designed for use in the bronchoscopy suite in conjunction with the Chartis Catheter. The Chartis Catheter is a previously cleared device (under K111522) and the subject 510(k) K180011 is solely for the Chartis Tablet Console. The proximal end of the Chartis Catheter is attached to a polymer tube with a filter whose opposite end is attached to an input fitting on the Chartis Console. The balloon on the Chartis Catheter isolates the lung compartment of interest. The hardware components of the Tablet Console translate airflow and pressure detected through the Chartis Catheter into electrical signals. The Tablet Console analyzes and displays airflow and pressure from the isolated lung compartment in real time.
PULMONX CORPORATION
CHR-CO-300
In Commercial Distribution

  • 00811907031161 ()


  • Diagnostic spirometer, professional
The Chartis Tablet Console is a two-part spirometry system comprised of a touchscreen computer and sensor enclosure designed for use in the bronchoscopy suite in conjunction with the Chartis Catheter. The Chartis Catheter is a previously cleared device (under K111522) and the subject 510(k) K180011 is solely for the Chartis Tablet Console. The proximal end of the Chartis Catheter is attached to a polymer tube with a filter whose opposite end is attached to an input fitting on the Chartis Console. The balloon on the Chartis Catheter isolates the lung compartment of interest. The hardware components of the Tablet Console translate airflow and pressure detected through the Chartis Catheter into electrical signals. The Tablet Console analyzes and displays airflow and pressure from the isolated lung compartment in real time.
PULMONX CORPORATION
CHR-CO-300
In Commercial Distribution

  • 00811907031123 ()


  • Diagnostic spirometer, professional
The all.health Algo SaMD™ Model 1000 oximeter is a pulse oximeter configured to operate in Software as a Medical Device (“SaMD”). The software device is intended to run remotely as an optional cloud service component of a complete all.health ICM™ system, a non-medical-device clinical decision support system. The software device collects input from compatible remote hardware sensor bands or other sensors, then filters, analyzes, and validates the collected data to produce a clinical-grade pulse measurement of heart rate (HRp), respiration rate (RRp), and blood oxygenation (SpO2%) for output, including outlier rejection, averages, trends, and ranges over time for the purpose of remote patient monitoring. Medical Device Info. • Class II (enforcement discretion) medical device • Regulation: Oximeter, 870.2700 • Rx. Federal law (USA) restricts this product to sale by or on the order of a licensed practitioner.
All.health, Inc.
Model 1000
In Commercial Distribution

  • 00860010157008 ()
ALGO-m1000-SW (rev 0)

  • Pulse oximeter
PURE EP™ is a system consists of two main parts: the amplifier, and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
AE-0001-412
Not in Commercial Distribution

  • 08567500070008 ()
AE-0001-412

  • Cardiac electrophysiology analysis system
PURE EP™ is a system consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
AE-0001-412
In Commercial Distribution

  • 00856750007000 ()
PE-002-001-000

  • Cardiac electrophysiology analysis system
The USB-02 Dongle is the hardware key for Cardiospy software that makes possible the use of Cardiospy ECG Holter recorders (EC-2H, EC-3H or EC-12H) as a system and the management, procession and evaluation of the recorded row data. The universal analysis SW provides full disclosure ECG recordings on channels with a precise automatic QRS and PM detection, template and rhythm analysis, QRS classification, efficient ST, QT, AF, PM, HRV time and frequency based analysis with color coded display and printing with interactive modification possibilities in the automatic analysis in several languages. Export-import and archiving option of the recordings is available. The evaluation software works with a conventional PC- based computer under Win 2000/XP/VISTA , Windows 7, Windows 8, Windows 10 operating systems. The connection between the Holter and computer is performed by using Bluetooth and USB dongle. The Cardiospy analysis software provides ECG records of excellent quality.
LABTECH Kereskedelmi és Mérnöki Szolgáltató Korlátolt Felelősségű Társaság
USB-02 Dongle
In Commercial Distribution

  • 05999883490075 ()

  • Weight: 50 Gram
  • Width: 18.5 Millimeter
  • Width: 53 Millimeter
  • Length: 67.5 Millimeter
DEV-00USB-02

  • Electrocardiographic long-term ambulatory recording analyser
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-019
In Commercial Distribution

  • 10810098650264 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-017
In Commercial Distribution

  • 10810098650141 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-014
In Commercial Distribution

  • 10855728005915 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-010
In Commercial Distribution

  • 10855728005762 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-008
In Commercial Distribution

  • 10855728005656 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-003
In Commercial Distribution

  • 10855728005465 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 3028 IPG contains electronics and a battery that are sealed inside a titanium case. The IPG is implanted subcutaneously, below the clavicle in the upper chest, and connect to the stimulation lead and sensing lead. The Model 3028 does not contain any software or firmware. All functions including the telemetry and algorithm have been designed into the hardware of the IPG. The algorithm synchronizes stimulation of the hypoglossal nerve with respiration signals. The IPG processes the same dynamic range of pressure signals (2-48 cmH2O) in order to account for pressure reading variability. Based on typical settings from the STAR pivotal trial, the longevity of the Model 3028’s battery will average 10 years although the device is smaller than the currently approved version (Model 3024). In addition the Model 3028 IPG will allow patients to safely undergo magnetic resonance imaging (MRI) under specified conditions.
Inspire Medical Systems, Inc.
900-007-001
In Commercial Distribution

  • 10855728005366 ()
3028

  • Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
NKPW Psychophysiological biofeedback system A computerized device assembly designed for analysis and real-time feedback (biofeedback) of a variety of physiological parameters [e.g., heart rate, respiration, skin conductance, skin temperature, range of motion, force output, electroencephalography (EEG), electromyography (EMG), electrocardiography (ECG) data] to assist a patient in developing a degree of conscious control over typically involuntary functions, usually for relaxation training and muscle re-education. It includes multiple pieces of patient monitoring hardware (e.g., electrodes, sensors), computer interface devices, and dedicated software; it is intended to be used with an off-the-shelf computer. HJLM Biofeedback system application software An application software program designed for use in, or together with, a biofeedback system, so that it may function according to its intended purpose. This software program can be permanently installed, or exchanged as an upgrade. It may also be produced for installation in an off-the-shelf desktop or laptop computer.
Ochs Labs LLC
LW3
In Commercial Distribution

  • G253LW30 ()


  • Biofeedback system application software
The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system. A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.
MERIDIAN BIOSCIENCE, INC.
610210
In Commercial Distribution

  • 00840733102318 ()
610210

  • Thermal cycler nucleic acid amplification analyser IVD, laboratory
OsteoBoost is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, OsteoBoost resorbs and is later replaced by natural bone. It provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. OsteoBoost is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
OB-10P
In Commercial Distribution

  • 00816125023400 ()
OB-10P

  • Bone matrix implant, synthetic, non-antimicrobial
OsteoBoost is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, OsteoBoost resorbs and is later replaced by natural bone. It provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. OsteoBoost is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
OB-05P
In Commercial Distribution

  • 00816125023394 ()
OB-05P

  • Bone matrix implant, synthetic, non-antimicrobial
Vessel Analysis is a post-processing add-on module for ORS Visual that enables radiologists, cardiologists, vascular surgeons, and interventionalists to quickly and confidently evaluate CT angiographic studies. Vessel Analysis provides stenosis calculations, aneurysm quantification, and stent and stent-graft planning of the aorta, carotid, and renal arteries in an easy-to-use, intuitive screen that can simplify the clinical task of planning endovascular procedures. Advanced functionality such as automated vessel finding acts as a baseline for accurate vessel measurements and permits rapid segmentation of vessels. ORS Visual is a proprietary software application developed by Object Research Systems (ORS) Inc. that can be is used for the display and 3D visualization of medical image data derived from CT, MRI, and other modalities. It provides for the communication, storage, processing, rendering, and display of DICOM 3.0 compliant image data. ORS Visual, which is available in 32 and 64-bit versions, can be installed on a standard personal computer running the Windows operating system with the Microsoft ActiveX component and suitable graphics hardware.
Object Research Systems (ORS) Inc
ORS-VISU-VA01
In Commercial Distribution

  • B332VIVA0100 ()


  • Radiological PACS software
5 cables in one bag with 4 pin yoked jumper cables red to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-016-005
In Commercial Distribution

  • 00856750007178 ()
PE-002-016-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with 4 pin yoked jumper cables yellow to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-015-005
In Commercial Distribution

  • 00856750007161 ()
PE-002-015-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with 10 pin yoked jumper cables green to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-018-005
In Commercial Distribution

  • 00856750007154 ()
PE-002-018-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with 10 pin yoked jumper cables blue to split ECG signals between two ECG devices is an accessory to the PURE EP System The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-020-005
In Commercial Distribution

  • 00856750007147 ()
PE-002-020-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with 10 pin yoked jumper cables yellow to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-019-005
In Commercial Distribution

  • 00856750007130 ()
PE-002-019-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables black to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-017-005
In Commercial Distribution

  • 00856750007116 ()
PE-002-017-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables black to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-014-005
In Commercial Distribution

  • 00856750007109 ()
PE-002-014-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables red to split ECG signals between two ECG devices is an accessory to the PURE EP System The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-013-005
In Commercial Distribution

  • 00856750007093 ()
PE-002-013-005

  • Cardiac electrophysiology analysis system
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-10P
In Commercial Distribution

  • 00858418003270 ()
CemO-10P

  • Bone matrix implant, synthetic, non-antimicrobial
Cem-Ostetic is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, Cem-Ostetic resorbs and is later replaced by natural bone. Cem-Ostetic is a natural choice for sparing patients the trauma of autograft harvesting. It also provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. Cem-Ostetic is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
CemO-05P
In Commercial Distribution

  • 00858418003027 ()
CemO-05P

  • Bone matrix implant, synthetic, non-antimicrobial