SEARCH RESULTS FOR: 外链资源优化程序方法👉TG@yuantou2048👈谷歌外链发布10万条(181247 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

"MGB Alert® HSV Typer AS Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from HSV 1 and 2 (Herpes Simplex Virus 1 & 2). The mix consists of a total of 1.0 nmol of primers per vial in a 1X TE buffer solution. The primers amplify a 54 nucleic acid sequence from the glycoprotein D region of HSV 1 and 2."
Elitechgroup Mdx LLC
800518
In Commercial Distribution

  • 03661540951688 ()
800518

  • Herpes simplex virus 1 & 2 (HSV1 & 2) nucleic acid IVD, control
MGB Alert® Adenovirus Probe Mix is an analyte specific reagent that contains chemically synthesized DNA oligonucleotides designed to detect nucleic acid sequences within the hexon gene, which is present in all known Adenovirus types. The mix consists of two probes at 1.12 nmol per vial in a 1X TE buffer solution. The probes are labeled with 6-carboxyfluorescein, which has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm.
Elitechgroup Mdx LLC
800498
In Commercial Distribution

  • 03661540951671 ()
800498

  • Adenovirus nucleic acid IVD, kit, nucleic acid technique (NAT)
MGB Alert® Adenovirus Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from Adenovirus. The mix consists of a total of 3.3 nmol of primers per vial in a 1X TE buffer solution. The primers amplify the hexon gene, which covers all known Adenovirus types.
Elitechgroup Mdx LLC
800497
In Commercial Distribution

  • 03661540951664 ()
800497

  • Adenovirus nucleic acid IVD, kit, nucleic acid technique (NAT)
The MGB Alert Internal Control Set IC2-H consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2-H can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800496
In Commercial Distribution

  • 03661540951657 ()
800496

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC1-A consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC1-A can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800495
In Commercial Distribution

  • 03661540951640 ()
800495

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC1-V consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC1-V can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800439
In Commercial Distribution

  • 03661540951633 ()
800439

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC2-C consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2-C can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800432
In Commercial Distribution

  • 03661540951626 ()
800432

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC2-C consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2-C can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800431
In Commercial Distribution

  • 03661540951619 ()
800431

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC2-B consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2-B can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800430
In Commercial Distribution

  • 03661540951602 ()
800430

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC2 consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2 can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800429
In Commercial Distribution

  • 03661540951596 ()
800429

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC1 consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC1 can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800427
In Commercial Distribution

  • 03661540951589 ()
800427

  • Exogenous DNA/RNA internal control IVD, kit
MGB Alert® HSV 1 & 2 Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from HSV 1 and 2 (Herpes Simplex Virus 1 and 2). The mix consists of one probe at 0.2 nmol per vial in a 1X TE buffer solution. The probe dye is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm.
Elitechgroup Mdx LLC
800426
In Commercial Distribution

  • 03661540951572 ()
800426

  • Herpes simplex virus 1 & 2 (HSV1 & 2) nucleic acid IVD, control
"MGB Alert® HHV-6 Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from HHV-6. The mix consists of one probe at 0.5 nmol per vial in a 1X TE buffer solution. The probe is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm."
Elitechgroup Mdx LLC
800425
In Commercial Distribution

  • 03661540951565 ()
800425

  • Human herpesvirus 6 (HHV6) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® EBV Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from EBV (Epstein-Barr Virus). The mix consists of one probe at 0.5 nmol per vial in a 1X TE buffer solution. The probe is labeled with 6- carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm. "
Elitechgroup Mdx LLC
800424
In Commercial Distribution

  • 03661540951558 ()
800424

  • Epstein-Barr virus (EBV) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® CMV 3.0 Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from CMV (Cytomegalovirus). The probe is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm. "
Elitechgroup Mdx LLC
800423
In Commercial Distribution

  • 03661540951541 ()
800423

  • Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® BK Virus Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from BK Virus. The mix consists of one probe at 1.5 nmol per vial in a 1X TE buffer solution. The probe is labeled with 6- carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm."
Elitechgroup Mdx LLC
800421
In Commercial Distribution

  • 03661540951534 ()
800421

  • BK virus (BKV) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® VZV Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences within the ORF 38 region of VZV(Varicella-Zoster Virus). The mix consists of one probe at 0.5 nmol per vial in a 1X TE buffer solution. The probe is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm."
Elitechgroup Mdx LLC
800419
In Commercial Distribution

  • 03661540951527 ()
800419

  • Varicella-zoster virus (VZV) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® VZV Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from VZV (VaricellaZoster Virus). The mix consists of a total of 3.5 nmol of primers per vial in a 1X TE buffer solution. The primers amplify the VZV sequence within the ORF 38 region."
Elitechgroup Mdx LLC
800418
In Commercial Distribution

  • 03661540951510 ()
800418

  • Varicella-zoster virus (VZV) nucleic acid IVD, kit, nucleic acid technique (NAT)
MGB Alert® HSV 1 & 2 Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from HSV 1 and 2 (Herpes Simplex Virus 1 & 2). The mix consists of a total of 1.5 nmol of primers per vial in a 1X TE buffer solution. The primers amplify a 54 nucleic acid sequence from the glycoprotein D region of HSV 1 and 2.
Elitechgroup Mdx LLC
800416
In Commercial Distribution

  • 03661540951503 ()
800416

  • Herpes simplex virus 1 & 2 (HSV1 & 2) nucleic acid IVD, control
"MGB Alert® HHV-6 Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from HHV-6 (Human Herpesvirus 6). The mix consists of a total of 2.4 nmol of primers per vial in a 1X TE buffer solution. The primers amplify a 115 nucleic acid sequence from the U67 gene region of HHV-6. "
Elitechgroup Mdx LLC
800415
In Commercial Distribution

  • 03661540951497 ()
800415

  • Human herpesvirus 6 (HHV6) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® CMV 3.0 Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from the IE1 region of CMV (Cytomegalovirus). "
Elitechgroup Mdx LLC
800413
In Commercial Distribution

  • 03661540951473 ()
800413

  • Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
MGB Alert® BK Virus Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from BK Virus. The mix consists of a total of 2.6 nmol of primers per vial in a 1X TE buffer solution. The primers amplify a 72 nucleic acid sequence from the VP1 region of BK Virus.
Elitechgroup Mdx LLC
800411
In Commercial Distribution

  • 03661540951466 ()


  • BK virus (BKV) nucleic acid IVD, kit, nucleic acid technique (NAT)
"MGB Alert® CMV 3.0 Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from CMV (Cytomegalovirus). The probe is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm. "
Elitechgroup Mdx LLC
800404
In Commercial Distribution

  • 03661540951459 ()
800404

  • Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
The MGB Alert Internal Control Set MS2-E consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set MS2-E can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800365
In Commercial Distribution

  • 03661540951442 ()
800365

  • Exogenous RNA internal control kit IVD
The MGB Alert Internal Control Set MS2-M consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set MS2-M can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800364
In Commercial Distribution

  • 03661540951435 ()
800364

  • Exogenous RNA internal control kit IVD
The MGB Alert Internal Control Set IC2-B consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2-B can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800363
In Commercial Distribution

  • 03661540951428 ()
800363

  • Exogenous DNA/RNA internal control IVD, kit
The MGB Alert Internal Control Set IC2 consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control Set IC2 can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.
Elitechgroup Mdx LLC
800362
In Commercial Distribution

  • 03661540951411 ()
800362

  • Exogenous DNA/RNA internal control IVD, kit
MGB Alert® HSV 1 & 2 Probe Mix is an analyte specific reagent that contains a chemically synthesized DNA oligonucleotide designed to detect nucleic acid sequences from HSV 1 and 2 (Herpes Simplex Virus 1 and 2). The mix consists of one probe at 0.2 nmol per vial in a 1X TE buffer solution. The probe dye is labeled with 6-carboxyfluorescein and has an excitation wavelength maxima of 492 nm and an emission wavelength maxima of 516 nm.
Elitechgroup Mdx LLC
800355
In Commercial Distribution

  • 03661540951398 ()
800355

  • Herpes simplex virus 1 & 2 (HSV1 & 2) nucleic acid IVD, control
MGB Alert® HSV 1 & 2 Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from HSV 1 and 2 (Herpes Simplex Virus 1 & 2). The mix consists of a total of 1.5 nmol of primers per vial in a 1X TE buffer solution. The primers amplify a 54 nucleic acid sequence from the glycoprotein D region of HSV 1 and 2.
Elitechgroup Mdx LLC
800354
In Commercial Distribution

  • 03661540951381 ()
800354

  • Herpes simplex virus 1 & 2 (HSV1 & 2) nucleic acid IVD, control
"MGB Alert® CMV 3.0 Primer Mix contains chemically synthesized DNA oligonucleotides designed to amplify nucleic acid sequences from the IE1 region of CMV (Cytomegalovirus). "
Elitechgroup Mdx LLC
800350
In Commercial Distribution

  • 03661540951374 ()
800350

  • Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
< 1 ... 287 288 289 290 291 ... 334 >