SEARCH RESULTS FOR: (*cryptocurrency exchange hong kong馃挷itenthusiasts.com馃挷Enthusiasts*)(31022 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30080MW
In Commercial Distribution
- 04540778164314 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 80 mm
- Balloon Diameter; 3.0 mm
BD-B30080MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25080MW
In Commercial Distribution
- 04540778164291 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 80 mm
- Balloon Diameter; 2.5 mm
BD-B25080MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20080MW
In Commercial Distribution
- 04540778164277 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 80 mm
- Balloon Diameter; 2.0 mm
BD-B20080MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15080MW
In Commercial Distribution
- 04540778164253 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 80 mm
- Balloon Diameter; 1.5 mm
BD-B15080MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B40040MW
In Commercial Distribution
- 04540778164239 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 4.0 mm
BD-B40040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35040MW
In Commercial Distribution
- 04540778164215 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 3.5 mm
BD-B35040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30040MW
In Commercial Distribution
- 04540778164192 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 3.0 mm
BD-B30040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25040MW
In Commercial Distribution
- 04540778164178 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.5 mm
BD-B25040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20040MW
In Commercial Distribution
- 04540778164154 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.0 mm
BD-B20040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15040MW
In Commercial Distribution
- 04540778164130 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 1.5 mm
BD-B15040MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15020MW
In Commercial Distribution
- 04540778164116 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 1.5 mm
BD-B15020MW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B40200SW
In Commercial Distribution
- 04540778164093 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 200 mm
- Balloon Diameter; 4.0 mm
BD-B40200SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35200SW
In Commercial Distribution
- 04540778164079 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 200 mm
- Balloon Diameter; 3.5 mm
BD-B35200SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30200SW
In Commercial Distribution
- 04540778164055 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 200 mm
- Balloon Diameter; 3.0 mm
BD-B30200SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25200SW
In Commercial Distribution
- 04540778164031 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 200 mm
- Balloon Diameter; 2.5 mm
BD-B25200SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20200SW
In Commercial Distribution
- 04540778164017 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 200 mm
- Balloon Diameter; 2.0 mm
BD-B20200SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B40150SW
In Commercial Distribution
- 04540778163997 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 150 mm
- Balloon Diameter; 4.0 mm
BD-B40150SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35150SW
In Commercial Distribution
- 04540778163973 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 150 mm
- Balloon Diameter; 3.5 mm
BD-B35150SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30150SW
In Commercial Distribution
- 04540778163959 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 150 mm
- Balloon Diameter; 3.0 mm
BD-B30150SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25150SW
In Commercial Distribution
- 04540778163935 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 150 mm
- Balloon Diameter; 2.5 mm
BD-B25150SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20150SW
In Commercial Distribution
- 04540778163911 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 150 mm
- Balloon Diameter; 2.0 mm
BD-B20150SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B40120SW
In Commercial Distribution
- 04540778163898 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 4.0 mm
BD-B40120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35120SW
In Commercial Distribution
- 04540778163874 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 3.5 mm
BD-B35120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30120SW
In Commercial Distribution
- 04540778163850 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 3.0 mm
BD-B30120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25120SW
In Commercial Distribution
- 04540778163836 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 2.5 mm
BD-B25120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20120SW
In Commercial Distribution
- 04540778163812 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 2.0 mm
BD-B20120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15120SW
In Commercial Distribution
- 04540778163799 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 120 mm
- Balloon Diameter; 1.5 mm
BD-B15120SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B40080SW
In Commercial Distribution
- 04540778163775 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 80 mm
- Balloon Diameter; 4.0 mm
BD-B40080SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35080SW
In Commercial Distribution
- 04540778163751 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 80 mm
- Balloon Diameter; 3.5 mm
BD-B35080SW
- Peripheral angioplasty balloon catheter, basic
CROSPERIO OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30080SW
In Commercial Distribution
- 04540778163737 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.8 Fr
- Catheter Working Length; 650 mm
- Balloon Length; 80 mm
- Balloon Diameter; 3.0 mm
BD-B30080SW
- Peripheral angioplasty balloon catheter, basic