Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60200ER
In Commercial Distribution

  • 04540778175778 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 6.0 mm
BD-Q60200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50200ER
In Commercial Distribution

  • 04540778175754 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 5.0 mm
BD-Q50200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40200ER
In Commercial Distribution

  • 04540778175730 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 4.0 mm
BD-Q40200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30200ER
In Commercial Distribution

  • 04540778175716 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 3.0 mm
BD-Q30200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25200ER
In Commercial Distribution

  • 04540778175693 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 2.5 mm
BD-Q25200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20200ER
In Commercial Distribution

  • 04540778175679 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 2.0 mm
BD-Q20200ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60150ER
In Commercial Distribution

  • 04540778175655 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 6.0 mm
BD-Q60150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50150ER
In Commercial Distribution

  • 04540778175631 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 5.0 mm
BD-Q50150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40150ER
In Commercial Distribution

  • 04540778175617 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 4.0 mm
BD-Q40150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30150ER
In Commercial Distribution

  • 04540778175594 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 3.0 mm
BD-Q30150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25150ER
In Commercial Distribution

  • 04540778175570 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 2.5 mm
BD-Q25150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20150ER
In Commercial Distribution

  • 04540778175556 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 2.0 mm
BD-Q20150ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60120ER
In Commercial Distribution

  • 04540778175532 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 6.0 mm
BD-Q60120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50120ER
In Commercial Distribution

  • 04540778175518 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 5.0 mm
BD-Q50120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40120ER
In Commercial Distribution

  • 04540778175495 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 4.0 mm
BD-Q40120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30120ER
In Commercial Distribution

  • 04540778175471 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 3.0 mm
BD-Q30120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25120ER
In Commercial Distribution

  • 04540778175457 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 2.5 mm
BD-Q25120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20120ER
In Commercial Distribution

  • 04540778175433 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 120 mm
  • Balloon Diameter; 2.0 mm
BD-Q20120ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60100ER
In Commercial Distribution

  • 04540778175419 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 6.0 mm
BD-Q60100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50100ER
In Commercial Distribution

  • 04540778175396 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 5.0 mm
BD-Q50100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40100ER
In Commercial Distribution

  • 04540778175372 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 4.0 mm
BD-Q40100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30100ER
In Commercial Distribution

  • 04540778175358 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 3.0 mm
BD-Q30100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25100ER
In Commercial Distribution

  • 04540778175334 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 2.5 mm
BD-Q25100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20100ER
In Commercial Distribution

  • 04540778175310 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 100 mm
  • Balloon Diameter; 2.0 mm
BD-Q20100ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60080ER
In Commercial Distribution

  • 04540778175297 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 6.0 mm
BD-Q60080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50080ER
In Commercial Distribution

  • 04540778175273 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 5.0 mm
BD-Q50080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40080ER
In Commercial Distribution

  • 04540778175259 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 4.0 mm
BD-Q40080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30080ER
In Commercial Distribution

  • 04540778175235 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 3.0 mm
BD-Q30080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25080ER
In Commercial Distribution

  • 04540778175211 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 2.5 mm
BD-Q25080ER

  • Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20080ER
In Commercial Distribution

  • 04540778175198 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 80 mm
  • Balloon Diameter; 2.0 mm
BD-Q20080ER

  • Peripheral angioplasty balloon catheter, basic