As packaged, NEOVEIL is a suture- and staple-reinforcement product composed of 100% bioabsorbable polyglycolic acid (PGA). This nonwoven product is dyed with D&C Green No.6 in order to make it readily visible to the surgeon.
Two forms of NEOVEIL are provided. The Tube type model constitutes of pre-formed porous bio-absorbable nonwoven sheets and is intended for staple-line reinforcement. The Tube type model is provided in the form of sleeves, one for the cartridge and one for the anvil on a corresponding stapler. After deployment of the tube type reinforcement material, the non-degradable elastic knits, comprised of polyurethane and nylon, are removed and discarded along with the PGA tacking sutures. The Sheet type model is simply a porous fibrous bio-absorbable sheet which is intended for suture-line reinforcement. The thickness of the bioabsorbable NEOVEIL staple line reinforcement ranges from 0.1 mm to 0.85 mm.
Mesh weave characteristics and pore size are not applicable since NEOVEIL is nonwoven material. Average basis weight of the NEOVEIL model ranges from 35 to 225 (g/m2).
GUNZE LIMITED
NV-ET-M60E-2
In Commercial Distribution
- 04547301462558 ()
- Length: 60 Millimeter
- Width: 18 Millimeter
NV-ET-M60E-2
- Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable
As packaged, NEOVEIL is a suture- and staple-reinforcement product composed of 100% bioabsorbable polyglycolic acid (PGA). This nonwoven product is dyed with D&C Green No.6 in order to make it readily visible to the surgeon.
Two forms of NEOVEIL are provided. The Tube type model constitutes of pre-formed porous bio-absorbable nonwoven sheets and is intended for staple-line reinforcement. The Tube type model is provided in the form of sleeves, one for the cartridge and one for the anvil on a corresponding stapler. After deployment of the tube type reinforcement material, the non-degradable elastic knits, comprised of polyurethane and nylon, are removed and discarded along with the PGA tacking sutures. The Sheet type model is simply a porous fibrous bio-absorbable sheet which is intended for suture-line reinforcement. The thickness of the bioabsorbable NEOVEIL staple line reinforcement ranges from 0.1 mm to 0.85 mm.
Mesh weave characteristics and pore size are not applicable since NEOVEIL is nonwoven material. Average basis weight of the NEOVEIL model ranges from 35 to 225 (g/m2).
GUNZE LIMITED
NV-ET-M60A-2
In Commercial Distribution
- 04547301462534 ()
- Length: 60 Millimeter
- Width: 17 Millimeter
NV-ET-M60A-2
- Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable
The QUART arterial filter (HBF 140) with SOFTLINE coating, sterile, is a screen filter with integrated bypass and pre-postdeairing mechanic. It is used for removing gaseous embolisms and aggregates from blood components of the arterial bloodline during extracorporeal circulation. Therefore utilization of the arterial filter reduces the patient’s risk of injury from a micro embolism caused by gases or solids.
Maquet Cardiopulmonary AG
BO-HBF 140, SOFTLINE, Sterile
Not in Commercial Distribution
- 04037691117911 ()
- 04037691253862 ()
- Area/Surface Area: 570 Square centimeter
- maximum blood flow [l/min] 7 0
- connection size inlet 3/8 Inch
- connection size outlet 3/8 Inch
- priming volume 180 Milliliter
- Pore Size: 40 Micrometer
70103.2033
- Blood transfusion filter
QUART Arterial Filter with BIOLINE Coating, Sterile. The QUART arterial filter (HBF 140) is a screen filter with integrated bypass and pre-postdeairing mechanic. It is used for removing gaseous embolisms and aggregates from blood components of the arterial bloodline during extracorporeal circulation. Therefore utilization of the arterial filter reduces the patient’s risk of injury from a micro embolism caused by gases or solids.
Maquet Cardiopulmonary AG
BEQ-HBF 140 Arterial Filter, Sterile
Not in Commercial Distribution
- 04037691173412 ()
- 04037691173405 ()
- Area/Surface Area: 570 Square centimeter
- maximum blood flow [l/min] 7 0
- connection size inlet 3/8 Inch
- connection size outlet 3/8 Inch
- priming volume 180 Milliliter
- Pore Size: 40 Micrometer
70101.2811
- Blood transfusion filter
Quart Arterial Filter, no coating, HBF 140#Arterieller Filter Quart
Maquet Cardiopulmonary AG
QUART Arterial Filter
Not in Commercial Distribution
- 04037691190402 ()
- 04037691078977 ()
- 04037691004907 ()
- Pore Size: 40 Micrometer
- priming volume 180 Milliliter
- connection size outlet 3/8 Inch
- connection size inlet 3/8 Inch
- maximum blood flow [l/min] 7 0
- Area/Surface Area: 570 Square centimeter
70100.4263
- Blood transfusion filter
FILTER 61399401153 AFFINITY 6CA ART 352
MEDTRONIC, INC.
61399401153
In Commercial Distribution
- 20643169767762 ()
- 00643169767751 ()
- Pore Size: 38.0 Micrometer
- Cardiopulmonary bypass system filter, arterial blood line
FILTER 61399409503 AFFINITY ART 354 6PK
MEDTRONIC, INC.
61399409503
In Commercial Distribution
- 20643169767748 ()
- 00643169767737 ()
- Pore Size: 20.0 Micrometer
- Cardiopulmonary bypass system filter, arterial blood line
FILTER CB4014 AFF PED ART CC ST CEM 4PK
MEDTRONIC, INC.
CB4014
In Commercial Distribution
- 20643169767724 ()
- 00643169767713 ()
- Cardiopulmonary bypass system filter, arterial blood line
No Description
TERUMO CORPORATION
CX*VRA1001T2
In Commercial Distribution
- 34987350706691 ()
- 04987350706690 ()
- Cardiotomy reservoir
No Description
TERUMO CORPORATION
CX*VRA0701T2
In Commercial Distribution
- 34987350706592 ()
- 04987350706591 ()
- Cardiotomy reservoir
No Description
TERUMO CORPORATION
CX*VRA0401T2
In Commercial Distribution
- 34987350706493 ()
- 04987350706492 ()
- Cardiotomy reservoir
No Description
TERUMO CORPORATION
CX*VRA0101T2
In Commercial Distribution
- 34987350706394 ()
- 04987350706393 ()
- Cardiotomy reservoir
No Description
TERUMO CORPORATION
CX*AF02
In Commercial Distribution
- 54987350705636 ()
- 04987350705631 ()
- Cardiopulmonary bypass system filter, arterial blood line
As packaged, NEOVEIL is a suture- and staple-reinforcement product composed of 100% bioabsorbable polyglycolic acid (PGA). This nonwoven product is dyed with D&C Green No.6 in order to make it readily visible to the surgeon.
Two forms of NEOVEIL are provided. The Tube type model constitutes of pre-formed porous bio-absorbable nonwoven sheets and is intended for staple-line reinforcement. The Tube type model is provided in the form of sleeves, one for the cartridge and one for the anvil on a corresponding stapler. After deployment of the tube type reinforcement material, the non-degradable elastic knits, comprised of polyurethane and nylon, are removed and discarded along with the PGA tacking sutures. The Sheet type model is simply a porous fibrous bio-absorbable sheet which is intended for suture-line reinforcement. The thickness of the bioabsorbable NEOVEIL staple line reinforcement ranges from 0.1 mm to 0.85 mm.
Mesh weave characteristics and pore size are not applicable since NEOVEIL is nonwoven material. Average basis weight of the NEOVEIL model ranges from 35 to 225 (g/m2).
GUNZE LIMITED
NV-ET-M60L-3
In Commercial Distribution
- 04973077713783 ()
- Length: 60 Millimeter
- Width: 17 Millimeter
NV-ET-M60L-3
- Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable
NEOVEIL Staple Line Reinforcement is composed of a biodegradable synthetic polymer, polyglycolic acid(PGA) and is offered as a nonwoven surgical mesh configured into sleeves. The device is applied to the surgical site via a mechanical stapler with two jaws, where one piece of the sleeve is slid over each jaw of the stapler. This is accomplished by attaching a similar-sized piece of nonabsorbable elastic knit to the PGA felt that is held together by means of PGA tacking threads. After deployment of the tube type reinforcement material, the non-degradable elastic knits, comprised of polyurethane and nylon, are removed and discarded along with the PGA tacking sutures. The PGA material is dyed with D&C Green No.6.
GUNZE LIMITED
NV-ET-M60E-3
In Commercial Distribution
- 04973077713776 ()
- Length: 60 Millimeter
- Width: 17 Millimeter
NV-ET-M60E-3
- Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable
FILTER BB851 AF100 WITH BALANCE
MEDTRONIC, INC.
BB851
In Commercial Distribution
- 20643169178124 ()
- 00643169178120 ()
- Cardiopulmonary bypass system filter, arterial blood line
FILTER CB851 AF100 WITH CARMEDA
MEDTRONIC, INC.
CB851
Not in Commercial Distribution
- 20643169178032 ()
- 00643169178038 ()
- Cardiopulmonary bypass system filter, arterial blood line
ARTERIAL FILTER BB4014PEDS BB STERILE
MEDTRONIC, INC.
BB4014
In Commercial Distribution
- 20643169878123 ()
- 00643169878129 ()
- Cardiopulmonary bypass system filter, arterial blood line
FILTER CB851 AF100 WITH CORTIVA 26L
MEDTRONIC, INC.
CB851
In Commercial Distribution
- 20643169878116 ()
- 00643169878112 ()
- Cardiopulmonary bypass system filter, arterial blood line
FILTER S4014 AFFINITYPEDIATRIC ART ST
MEDTRONIC, INC.
S4014
In Commercial Distribution
- 20643169858910 ()
- 00643169858916 ()
- Cardiopulmonary bypass system filter, arterial blood line