SEARCH RESULTS FOR: ablation(30420 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

REUSABLE GROUNDING PAD CABLES
Conmed Corporation
T210
In Commercial Distribution

T210

  • Electrosurgical return lead
REUSABLE GROUNDING PAD CABLES
Conmed Corporation
T205
In Commercial Distribution

T205

  • Electrosurgical return lead
3.00MM DIA., HYDRO THERMAL ABLATION FIBEROPTIC ENDOSCOPE WITH SCOPE ADAPTER FOR HTA SHEET - AUTOCLAVABLE
ELMED INCORPORATED
52-4211
In Commercial Distribution

  • 00842180136731 ()
52-4211

  • Rigid optical laparoscope
Ablation Cable from SMARTABLATE System to CELSIUS Catheter or CARTO XP System PIU (DS)
STRYKER SUSTAINABILITY SOLUTIONS, INC.
N/A
In Commercial Distribution

  • 07613327515794 ()

  • Length: 10.0 Feet
D130303

  • Electrical-only medical device connection cable, reprocessed
GENERATOR AFR-00008 HEXAPULSE PF US
MEDTRONIC, INC.
AFR-00008
In Commercial Distribution

  • 00763000871925 ()


  • Cardiac irreversible electroporation system generator
IRRIGATION PUMP AFR-00005 HEXAFLOW US
MEDTRONIC, INC.
AFR-00005
In Commercial Distribution

  • 00763000871895 ()


  • Basic roller pump
CABLE AFR-00006 EXTENSION 1PK US
MEDTRONIC, INC.
AFR-00006
In Commercial Distribution

  • 00763000871802 ()


  • Electrical-only medical device connection cable, single-use
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure. The needle is hollow and its inner space is divided into 3 concentric lumens: • the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula); • the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple; • the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit. The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI1005
In Commercial Distribution

  • 00860011603610 ()


  • Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure. The needle is hollow and its inner space is divided into 3 concentric lumens: • the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula); • the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple; • the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit. The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI0704
In Commercial Distribution

  • 00860011603603 ()


  • Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Avanos Medical, Inc.
PMP-18-145
In Commercial Distribution

  • 40680651986786 ()
  • 00680651986788 ()
PMP-18-145

  • Percutaneous radio-frequency ablation probe cannula, single-use
< 1 ... 481 482 483 484 485 ... 1000 >