SEARCH RESULTS FOR: ablation(30420 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Vesta RF Cannula
Stratus Medical LLC
NLT-100-18-10-CS
In Commercial Distribution
- 40850040767061 ()
- 00850040767063 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Vesta RF Cannula
Stratus Medical LLC
NLT-100-18-10-CH
In Commercial Distribution
- 40850040767054 ()
- 00850040767056 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Vesta RF Cannula
Stratus Medical LLC
NLT-100-18-10-BB
In Commercial Distribution
- 50850040767044 ()
- 00850040767049 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Electrosurgical RF Multitined Expandable Electrode
Stratus Medical LLC
NIM-050-10BB
In Commercial Distribution
- 10850040767039 ()
- 00850040767032 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Electrosurgical RF Multitined Expandable Electrode
Stratus Medical LLC
NIM-150-10BB
In Commercial Distribution
- 10850040767022 ()
- 00850040767025 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Electrosurgical RF Multitined Expandable Electrode
Stratus Medical LLC
NIM-100-10BB-CS
In Commercial Distribution
- 10850040767015 ()
- 00850040767018 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Electrosurgical RF Multitined Expandable Electrode
Stratus Medical LLC
NIM-100-10BB
In Commercial Distribution
- 10850040767008 ()
- 00850040767001 ()
- Percutaneous radio-frequency ablation probe cannula, single-use
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI1005
In Commercial Distribution
- 00860011603610 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
Spinery (RF) Needles are composed by a handle with electrode cooled needle and are offered in bipolar configurations. The available variants consist of cooled needles capable of providing irrigation of tissue through needle tip during ablation procedure.
The needle is hollow and its inner space is divided into 3 concentric lumens:
• the inner central lumen is used to distally deliver the irrigation solution to the tip of the RF needle; a hole on the needle tip allows the irrigation solution to reach tissues (the irrigation solution could be also delivered proximally through the insulation and irrigation cannula);
• the intermediate lumen is used to deliver a cooling fluid through the proximal SpineryTM RF Ablation System by Axon Spine Medical Systems thermocouple;
• the outer external lumen returns the cooling fluid from the proximal thermocouple towards the cooling tubing circuit connected to the handle of the RF needle device; the cooling fluid is not intended to come in contact with patient tissue because it flows in a closed circuit.
The needles also contain two thermocouples, a distal thermocouple inside the ablation area and proximal thermocouple at the edge of ablation area that permit real-time monitoring of temperatures at the center of the ablation zone and at the edge of ablation area ensuring that no healthy tissue around tumor is damaged.
AXON SRL
SP-BI0704
In Commercial Distribution
- 00860011603603 ()
- Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar
No Description
Avanos Medical, Inc.
PMP-18-145
In Commercial Distribution
- 40680651986786 ()
- 00680651986788 ()
PMP-18-145