Safety lancets are sterile, single use medical devices intended for capillary blood sampling. Intended users are healthcare professionals and lay users.
HTL STREFA S A
21G x 2.4mm
In Commercial Distribution
- 15903999602113 ()
- 05903999602116 ()
- 85903999602112 ()
9673
- Blood lancet, single-use
Safety lancets are sterile, single use medical devices intended for capillary blood sampling. Intended users are healthcare professionals and lay users.
HTL STREFA S A
25G x 1.5mm
In Commercial Distribution
- 15903999602090 ()
- 05903999602093 ()
- 85903999602099 ()
9671
- Blood lancet, single-use
Safety lancets are sterile, single use medical devices intended for capillary blood sampling. Intended users are healthcare professionals and lay users.
HTL STREFA S A
30G x 1.2mm
In Commercial Distribution
- 15903999602076 ()
- 05903999602079 ()
- 85903999602075 ()
9669
- Blood lancet, single-use
The Dropsafe® Safety Needle is used for general purpose injection and aspiration of fluids from vials, ampules and parts of the body below the surface of the skin.
HTL STREFA S A
23G x 1"
In Commercial Distribution
- 15907996099969 ()
- 05907996099962 ()
- 25907996099966 ()
6069
- Hypodermic needle, single-use
The Dropsafe® Safety Needle is used for general purpose injection and aspiration of fluids from vials, ampules and parts of the body below the surface of the skin.
HTL STREFA S A
25G x 1”
In Commercial Distribution
- 05907996099955 ()
- 15907996099952 ()
- 25907996099959 ()
6068
- Hypodermic needle, single-use
100 pcs sterile single use DropSafe pen needles per box, intended for use with pen injector devices for the injection of drugs.
HTL STREFA S A
31G x 5mm
In Commercial Distribution
- 85907996098589 ()
- 05907996098583 ()
- 15907996098580 ()
8161
- Autoinjector needle
90 pcs sterile, single use droplet pen needles per box, intended to be used with a pen injector device for the subcutaneous injection of drugs.
HTL STREFA S A
29G x 12mm
In Commercial Distribution
- 05907996098071 ()
- 85907996098077 ()
7874
- Autoinjector needle
No Description
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
TE X Lite
In Commercial Distribution
- 06903053003919 ()
- General-purpose ultrasound imaging system
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.0 x 60mm
In Commercial Distribution
- 00195451000171 ()
- M732M5IVL60600 ()
- Balloon Diameter: 6.0 Millimeter
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Length: 60 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Catheter Working Length: 110 Centimeter
- Introducer Sheath Compatibility: 6 French
M5IVL6060
- Intravascular lithotripsy system balloon catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.5 x 60mm
In Commercial Distribution
- 00195451000164 ()
- M732M5IVL55600 ()
- Introducer Sheath Compatibility: 6 French
- Catheter Working Length: 110 Centimeter
- Balloon Proximal Outer Diameter (OD): 0.064 Inch
- Balloon Length: 60 Millimeter
- Balloon Rated Burst Pressure: 10 Atmosphere
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Guidewire Diameter: 0.014 Inch
- Balloon Diameter: 5.5 Millimeter
M5IVL5560
- Intravascular lithotripsy system balloon catheter, peripheral