Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Sierra Screw,4.5 Dia x 30mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4530
Not in Commercial Distribution

  • 10889981042820 ()

  • 4.5 Dia X 30mm
50-4530

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 28mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4528
In Commercial Distribution

  • 10889981042813 ()

  • 4.5 Dia X 28mm
50-4528

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 26mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4526
Not in Commercial Distribution

  • 10889981042806 ()

  • 4.5 Dia X 26mm
50-4526

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 24mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4524
In Commercial Distribution

  • 10889981042790 ()

  • 4.5 Dia X 24mm
50-4524

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 22mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4522
Not in Commercial Distribution

  • 10889981042783 ()

  • 4.5 Dia X 22mm
50-4522

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 20mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4520
In Commercial Distribution

  • 10889981042776 ()

  • 4.5 Dia X 20mm
50-4520

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 18mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4518
Not in Commercial Distribution

  • 10889981042769 ()

  • 4.5 Dia X 18mm
50-4518

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 16mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4516
Not in Commercial Distribution

  • 10889981042752 ()

  • 4.5 Dia X 16mm
50-4516

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 14mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4514
Not in Commercial Distribution

  • 10889981042745 ()

  • 4.5 Dia X 14mm
50-4514

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 12mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4512
Not in Commercial Distribution

  • 10889981042738 ()

  • 4.5 Dia X 12mm
50-4512

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 10mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4510
In Commercial Distribution

  • 10889981042721 ()

  • 4.5 Dia X 10mm
50-4510

  • Cannulated surgical drill bit, single-use
Sierra Screw,4.5 Dia x 8mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4508
Not in Commercial Distribution

  • 10889981042714 ()

  • 4.5 Dia X 8mm
50-4508

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 40mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4040
Not in Commercial Distribution

  • 10889981042707 ()

  • 4.0 Dia X 40mm
50-4040

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 38mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4038
Not in Commercial Distribution

  • 10889981042691 ()

  • 4.0 Dia X 38mm
50-4038

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 36mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4036
Not in Commercial Distribution

  • 10889981042684 ()

  • 4.0 Dia X 36mm
50-4036

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 34mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4034
Not in Commercial Distribution

  • 10889981042677 ()

  • 4.0 Dia X 34mm
50-4034

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 32mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4032
Not in Commercial Distribution

  • 10889981042660 ()

  • 4.0 Dia X 32mm
50-4032

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 30mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4030
Not in Commercial Distribution

  • 10889981042653 ()

  • 4.0 Dia X 30mm
50-4030

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 28mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4028
In Commercial Distribution

  • 10889981042646 ()

  • 4.0 Dia X 28mm
50-4028

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 26mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4026
In Commercial Distribution

  • 10889981042639 ()

  • 4.0 Dia X 26mm
50-4026

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 24mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4024
In Commercial Distribution

  • 10889981042622 ()

  • 4.0 Dia X 24mm
50-4024

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 22mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4022
In Commercial Distribution

  • 10889981042615 ()

  • 4.0 Dia X 22mm
50-4022

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 20mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4020
In Commercial Distribution

  • 10889981042608 ()

  • 4.0 Dia X 20mm
50-4020

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 18mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4018
In Commercial Distribution

  • 10889981042592 ()

  • 4.0 Dia X 18mm
50-4018

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 16mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4016
In Commercial Distribution

  • 10889981042585 ()

  • 4.0 Dia X 16mm
50-4016

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 14mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4014
In Commercial Distribution

  • 10889981042578 ()

  • 4.0 Dia X 14mm
50-4014

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 12mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4012
In Commercial Distribution

  • 10889981042561 ()

  • 4.0 Dia X 12mm
50-4012

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 10mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4010
In Commercial Distribution

  • 10889981042554 ()

  • 4.0 Dia X 10mm
50-4010

  • Cannulated surgical drill bit, single-use
Sierra Screw, 04.0 x 8mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-4008
Not in Commercial Distribution

  • 10889981042547 ()

  • 4.0 Dia X 8mm
50-4008

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 40mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3540
Not in Commercial Distribution

  • 10889981042530 ()

  • 3.5 Dia X 40mm
50-3540

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 38mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3538
Not in Commercial Distribution

  • 10889981042523 ()

  • 3.5 Dia X 38mm
50-3538

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 36mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3536
Not in Commercial Distribution

  • 10889981042516 ()

  • 3.5 Dia X 36mm
50-3536

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 34mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3534
Not in Commercial Distribution

  • 10889981042509 ()

  • 3.5 Dia X 34mm
50-3534

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 32mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3532
In Commercial Distribution

  • 10889981042493 ()

  • 3.5 Dia X 32mm
50-3532

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 30mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3530
In Commercial Distribution

  • 10889981042486 ()

  • 3.5 Dia X 30mm
50-3530

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 28mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3528
In Commercial Distribution

  • 10889981042479 ()

  • 3.5 Dia X 28mm
50-3528

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 26mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3526
In Commercial Distribution

  • 10889981042462 ()

  • 3.5 Dia X 26mm
50-3526

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 24mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3524
In Commercial Distribution

  • 10889981042455 ()

  • 3.5 Dia X 24mm
50-3524

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 22mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3522
In Commercial Distribution

  • 10889981042448 ()

  • 3.5 Dia X 22mm
50-3522

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 20mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3520
In Commercial Distribution

  • 10889981042431 ()

  • 3.5 Dia X 20mm
50-3520

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 18mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3518
In Commercial Distribution

  • 10889981042424 ()

  • 3.5 Dia X 18mm
50-3518

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 16mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3516
In Commercial Distribution

  • 10889981042417 ()

  • 3.5 Dia X 16mm
50-3516

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 14mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3514
In Commercial Distribution

  • 10889981042400 ()

  • 3.5 Dia X 14mm
50-3514

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 12mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3512
In Commercial Distribution

  • 10889981042394 ()

  • 3.5 Dia X 12mm
50-3512

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 10mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3510
In Commercial Distribution

  • 10889981042387 ()

  • 3.5 Dia X 10mm
50-3510

  • Cannulated surgical drill bit, single-use
Sierra Screw, 03.5 x 8mm. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-3508
Not in Commercial Distribution

  • 10889981042370 ()

  • 3.5 Dia X 8mm
50-3508

  • Cannulated surgical drill bit, single-use
Contoured Crossbar, Xlarge, 3.5 Rod. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-2014
In Commercial Distribution

  • 10889981042363 ()

  • 3.5
50-2014

  • Cannulated surgical drill bit, single-use
Contoured Crossbar, Large, 3.5 Rod. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-2013
In Commercial Distribution

  • 10889981042356 ()

  • 3.5
50-2013

  • Cannulated surgical drill bit, single-use
Contoured Crossbar, Medium, 3.5 Rod. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-2012
In Commercial Distribution

  • 10889981042349 ()

  • 3.5
50-2012

  • Cannulated surgical drill bit, single-use
Contoured Crossbar, Small, 3.5 Rod. The Sierra occipito-cervico-thoracic (OCT) spinal fixation system, including polyaxial screws, rods, locking caps, occipital plates, occipital screws, lateral connectors, contoured crossbars, hooks, and components, is used to provide stabilization of the spine in order to permit the biological process of spinal fusion to occur. Accepted standard techniques of spinal fusion are an integral part of the implantation of this system.
Seaspine Orthopedics Corporation
50-2011
In Commercial Distribution

  • 10889981042332 ()

  • 3.5
50-2011

  • Cannulated surgical drill bit, single-use
< 1 ... 7 8 9 10 11 ... 200 >