SEARCH RESULTS FOR: 新茶直播(下载网址:K782.com).5mi587t9.x视频(打开网站:K782.com).m16t(462409 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
2.5mm x 40mm
Not in Commercial Distribution

  • M732S4IVL25400 ()

  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Guidewire Diameter: 0.014 Inch
  • Introducer Sheath Compatibility: 5 French
  • Balloon Length: 40 Millimeter
  • Balloon Diameter: 2.5 Millimeter
  • Balloon Proximal Outer Diameter (OD): 0.052 Inch
  • Catheter Working Length: 135 Centimeter
S4IVL2540

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.5mm x 60mm
Not in Commercial Distribution

  • M732M5IVL65600 ()

  • Catheter Working Length: 110 Centimeter
  • Balloon Length: 60 Millimeter
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Guidewire Diameter: 0.014 Inch
  • Balloon Proximal Outer Diameter (OD): 0.072 Inch
  • Introducer Sheath Compatibility: 7 French
  • Balloon Diameter: 6.5 Millimeter
M5IVL6560

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
6.0mm x 60mm
Not in Commercial Distribution

  • M732M5IVL60600 ()

  • Balloon Diameter: 6.0 Millimeter
  • Guidewire Diameter: 0.014 Inch
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Length: 60 Millimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Catheter Working Length: 110 Centimeter
  • Introducer Sheath Compatibility: 6 French
M5IVL6060

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.5mm x 60mm
Not in Commercial Distribution

  • M732M5IVL45600 ()

  • Balloon Diameter: 4.5 Millimeter
  • Introducer Sheath Compatibility: 6 French
  • Catheter Working Length: 110 Centimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Balloon Length: 60 Millimeter
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Guidewire Diameter: 0.014 Inch
M5IVL4560

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.0mm x 40mm
Not in Commercial Distribution

  • M732S4IVL40400 ()

  • Balloon Proximal Outer Diameter (OD): 0.054 Inch
  • Balloon Diameter: 4.0 Millimeter
  • Balloon Length: 40 Millimeter
  • Introducer Sheath Compatibility: 5 French
  • Guidewire Diameter: 0.014 Inch
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Balloon Rated Burst Pressure: 10 Atmosphere
S4IVL4040

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
3.0mm x 40mm
Not in Commercial Distribution

  • M732S4IVL30400 ()

  • Balloon Proximal Outer Diameter (OD): 0.052 Inch
  • Balloon Diameter: 3.0 Millimeter
  • Balloon Length: 40 Millimeter
  • Introducer Sheath Compatibility: 5 French
  • Guidewire Diameter: 0.014 Inch
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Balloon Rated Burst Pressure: 10 Atmosphere
S4IVL3040

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.5mm x 60mm
Not in Commercial Distribution

  • M732M5IVL55600 ()

  • Introducer Sheath Compatibility: 6 French
  • Catheter Working Length: 110 Centimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Balloon Length: 60 Millimeter
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Guidewire Diameter: 0.014 Inch
  • Balloon Diameter: 5.5 Millimeter
M5IVL5560

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
5.0mm x 60mm
Not in Commercial Distribution

  • M732M5IVL50600 ()

  • Guidewire Diameter: 0.014 Inch
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Length: 60 Millimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Catheter Working Length: 110 Centimeter
  • Introducer Sheath Compatibility: 6 French
  • Balloon Diameter: 5.0 Millimeter
M5IVL5060

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
4.0mm x 60mm
Not in Commercial Distribution

  • M732M5IVL40600 ()

  • Balloon Diameter: 4.0 Millimeter
  • Guidewire Diameter: 0.014 Inch
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Length: 60 Millimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Catheter Working Length: 110 Centimeter
  • Introducer Sheath Compatibility: 6 French
M5IVL4060

  • Ultrasound thrombolysis system catheter, peripheral
The Shockwave M5 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Shockwave Medical, Inc.
3.5mm x 60mm
Not in Commercial Distribution

  • M732M5IVL35600 ()

  • Introducer Sheath Compatibility: 6 French
  • Catheter Working Length: 110 Centimeter
  • Balloon Proximal Outer Diameter (OD): 0.064 Inch
  • Balloon Length: 60 Millimeter
  • Balloon Rated Burst Pressure: 10 Atmosphere
  • Balloon Nominal (Inflation) Pressure: 6 Atmosphere
  • Guidewire Diameter: 0.014 Inch
  • Balloon Diameter: 3.5 Millimeter
M5IVL3560

  • Ultrasound thrombolysis system catheter, peripheral
< 1 ... 905 906 907 908 909 ... 1000 >