Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

microTargeting LP+ Patient Lead, Sterile, for use with microTargting Electrodes
FHC, INC.
66-EL-LP-00258
In Commercial Distribution

  • 00873263002582 ()
66-EL-LP

  • Depth electrode
microTargeting Electrode Cable w/ Alligator Clips, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-01-00257
In Commercial Distribution

  • 00873263002575 ()
66-EL-EC-01

  • Depth electrode
microTargeting(TM) Electrode, 1x, sterile, single, D.ZAP(Z), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685Z-00254
In Commercial Distribution

  • 10873263002541 ()
  • 00873263002544 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34685Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, single, D.ZAP(L), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685L-00252
In Commercial Distribution

  • 10873263002527 ()
  • 00873263002520 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
34685L

  • Depth electrode
microTargeting(TM) Electrode, differential, sterile, single, 1 Meg for use with Frame and STar or MT Drive
FHC, INC.
34680R-00250
In Commercial Distribution

  • 10873263002503 ()
  • 00873263002506 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
34680R

  • Depth electrode
microTargeting(TM) Electrode, sterile, 1x, array, D.ZAP(Z) for use with Frame and STar or MT Drive
FHC, INC.
22675Z-00246
In Commercial Distribution

  • 10873263002466 ()
  • 00873263002469 ()

  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
22675Z

  • Depth electrode
microTargeting Array Electrode, 1x, sterile, D.ZAP(L) for use with Frame, STar or MT Drive
FHC, INC.
22675L-00244
In Commercial Distribution

  • 10873263002442 ()
  • 00873263002445 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
22675L

  • Depth electrode
microTargeting Array Electrode, sterile, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
22670R-00242
In Commercial Distribution

  • 10873263002428 ()
  • 00873263002421 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
22670R

  • Depth electrode
microTargeting Electrode Cable, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-00155
In Commercial Distribution

  • 00873263001554 ()
66-EL-EC

  • Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00151
In Commercial Distribution

  • 00873263001516 ()
FC1020

  • Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00139
In Commercial Distribution

  • 00873263001394 ()
FC1020

  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
EDSEP
Not in Commercial Distribution

  • M272EDSEP1 ()
  • 10381780037088 ()


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D5L25
Not in Commercial Distribution

  • M272AU8D5L251 ()
  • 10381780036531 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L5
Not in Commercial Distribution

  • M272AU8D10L51 ()
  • 10381780036524 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L25
Not in Commercial Distribution

  • M272AU8D10L251 ()
  • 10381780036517 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D5L25
Not in Commercial Distribution

  • M272AU6D5L251 ()
  • 10381780036456 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L5
Not in Commercial Distribution

  • M272AU6D10L51 ()
  • 10381780036449 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L25
Not in Commercial Distribution

  • M272AU6D10L251 ()
  • 10381780036432 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D5L25
Not in Commercial Distribution

  • M272AU4D5L251 ()
  • 10381780036326 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
Not in Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L25
Not in Commercial Distribution

  • M272AU4D10L251 ()
  • 10381780036302 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
40M08
Not in Commercial Distribution

  • M27240M081 ()
  • 10381780034766 ()

  • Insertion needle 64mm Length


  • Depth electrode
microTargeting™ Single Frame Platinum 6x Non Sterile
FHC, INC.
35325Z-00795
In Commercial Distribution

  • 10873263007959 ()
  • 00873263007952 ()

  • Outer Diameter: 0.86 Millimeter
  • Length: 271.4 Millimeter
  • Length: 263.4 Millimeter
  • Length: 3 Millimeter
  • Impedance: Megaohms
35325Z

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00755
In Commercial Distribution

  • 10873263007553 ()
  • 00873263007556 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 249.2 Millimeter
FC5000

  • Depth electrode
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00752
In Commercial Distribution

  • 10873263007522 ()
  • 00873263007525 ()

  • Length: 227.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 242.2 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2004

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00751
In Commercial Distribution

  • 10873263007515 ()
  • 00873263007518 ()

  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00750
In Commercial Distribution

  • 10873263007508 ()
  • 00873263007501 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00749
In Commercial Distribution

  • 10873263007492 ()
  • 00873263007495 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 261.5 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2001

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00746
In Commercial Distribution

  • 10873263007461 ()
  • 00873263007464 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00745
In Commercial Distribution

  • 10873263007454 ()
  • 00873263007457 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
22670

  • Depth electrode
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00129
Not in Commercial Distribution

  • 10873263001292 ()
  • 00873263001295 ()

  • Length: 227.2 Millimeter
  • Length: 242.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
FC2004

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00128
Not in Commercial Distribution

  • 10873263001285 ()
  • 00873263001288 ()

  • Length: 249.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 10 Millimeter
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00127
Not in Commercial Distribution

  • 10873263001278 ()
  • 00873263001271 ()

  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00126
Not in Commercial Distribution

  • 10873263001261 ()
  • 00873263001264 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
FC2001

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00125
Not in Commercial Distribution

  • 10873263001254 ()
  • 00873263001257 ()

  • Impedance: Megaohms
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00124
Not in Commercial Distribution

  • 10873263001247 ()
  • 00873263001240 ()

  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
22670

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00117
Not in Commercial Distribution

  • 10873263001179 ()
  • 00873263001172 ()

  • Length: 249.2 Millimeter
  • Length: 10 Millimeter
  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
FC5000

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
RD16R-SP48X-000
In Commercial Distribution

  • 00841823109781 ()
RD16R-SP48X-000

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
SD16R-SP47X-000
In Commercial Distribution

  • 00841823109767 ()
SD16R-SP47X-000

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
SD16R-SP49X-000
In Commercial Distribution

  • 00841823109743 ()
SD16R-SP49X-000

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
11
In Commercial Distribution

  • 00841823109729 ()
BF08R-SP05X-0BH

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
10
In Commercial Distribution

  • 00841823109712 ()
BF08R-SP21X-0C3

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
9
In Commercial Distribution

  • 00841823109705 ()
BF08R-SP61X-0C3

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
8
In Commercial Distribution

  • 00841823109699 ()
BF09R-SP05X-0BE

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
7
In Commercial Distribution

  • 00841823109682 ()
BF09R-SP21X-0CC

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
6
In Commercial Distribution

  • 00841823109675 ()
BF09R-SP61X-0CC

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
5
In Commercial Distribution

  • 00841823109668 ()
BF10R-SP05X-0BH

  • Depth electrode
No Description
Ad-Tech Medical Instrument Corporation
4
In Commercial Distribution

  • 00841823109651 ()
BF10R-SP21X-0C3

  • Depth electrode
< 1 ... 9 10 11 12 13 ... 17 >