primaLOK SP 10mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0110-00
In Commercial Distribution

  • 00813210021747 ()

  • Height: 10 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 8mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0108-00
In Commercial Distribution

  • 00813210021730 ()

  • Height: 8 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 6mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0106-00
In Commercial Distribution

  • 00813210021723 ()

  • Height: 6 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 28mm Medium Boxless Implant, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0828-00
In Commercial Distribution

  • 00813210021785 ()

  • Width: 28 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
EARP RETRACTOR TRAY. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-TRAY02-XXX
In Commercial Distribution

  • 00810135961103 ()


  • Surgical instrument/implant rack
EARP DISC RAKE The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DR
In Commercial Distribution

  • 00810135961042 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL CADDIE The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-TC
In Commercial Distribution

  • 00810135960915 ()


  • Surgical instrument/implant rack
RETRACTABLE OSTEOTOME. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-O
In Commercial Distribution

  • 00810135960649 ()


  • Orthopaedic osteotome
EARP FINAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-FI
In Commercial Distribution

  • 00810135960632 ()


  • General internal orthopaedic fixation system implantation kit
EARP INITIAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-II
In Commercial Distribution

  • 00810135960625 ()


  • General internal orthopaedic fixation system implantation kit
EARP INSTRUMENT AND IMPLANT TRAY. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-TRAY01-XXX
In Commercial Distribution

  • 00810135961097 ()


  • Surgical instrument/implant rack
EARP DISC RAKE ANGLED. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DRA
In Commercial Distribution

  • 00810135961059 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, IMPLANT CADDIE 22X45. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_2245
In Commercial Distribution

  • 00810135961035 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 22X40. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_2240
In Commercial Distribution

  • 00810135961028 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 22X35. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_2235
In Commercial Distribution

  • 00810135961011 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 18X45. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1845
In Commercial Distribution

  • 00810135961004 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 18X40. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1840
In Commercial Distribution

  • 00810135960991 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 18X35. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1835
In Commercial Distribution

  • 00810135960984 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 18X30. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1830
In Commercial Distribution

  • 00810135960977 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 14X40. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1440
In Commercial Distribution

  • 00810135960960 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 14X35. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1435
In Commercial Distribution

  • 00810135960953 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 14X30. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1430
In Commercial Distribution

  • 00810135960946 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 14X25. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1425
In Commercial Distribution

  • 00810135960939 ()


  • Surgical instrument/implant rack
EARP, DISC SPACER CADDIE. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DC
In Commercial Distribution

  • 00810135960922 ()


  • Surgical instrument/implant rack
EARP, TRIAL 22X35X14 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-1214
In Commercial Distribution

  • 00810135960908 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X12 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-1212
In Commercial Distribution

  • 00810135960892 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X14 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0614
In Commercial Distribution

  • 00810135960885 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X12 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0612
In Commercial Distribution

  • 00810135960878 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0610
In Commercial Distribution

  • 00810135960861 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1214
In Commercial Distribution

  • 00810135960854 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1212
In Commercial Distribution

  • 00810135960847 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0614
In Commercial Distribution

  • 00810135960830 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0612
In Commercial Distribution

  • 00810135960823 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0610
In Commercial Distribution

  • 00810135960816 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0008
In Commercial Distribution

  • 00810135960809 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 8 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X10 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0010
In Commercial Distribution

  • 00810135960793 ()

  • Depth: 14 Millimeter
  • Width: 35 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0008
In Commercial Distribution

  • 00810135960786 ()

  • Height: 8 Millimeter
  • Depth: 14 Millimeter
  • Width: 35 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X25X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1425-0008
In Commercial Distribution

  • 00810135960779 ()

  • Height: 8 Millimeter
  • Width: 25 Millimeter
  • Depth: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-002
In Commercial Distribution

  • 00810135960618 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 14MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-14
In Commercial Distribution

  • 00810135960601 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 12MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-12
In Commercial Distribution

  • 00810135960595 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 10MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-10
In Commercial Distribution

  • 00810135960588 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 8MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-08
In Commercial Distribution

  • 00810135960571 ()


  • General internal orthopaedic fixation system implantation kit
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar II
In Commercial Distribution

  • B516221340 ()
22134

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR I is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests). NYSSTAR I is able to record all eye movements, as well horizontal, as vertical and even rotary movements on option. The calibration carried out by NYSSTAR I is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar I
In Commercial Distribution

  • B516221280 ()
22128

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar V2.0
In Commercial Distribution

  • B516320980 ()
32098

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516311790 ()
31179

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516227090 ()
22709

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516222210 ()
22221

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar
In Commercial Distribution

  • B516221350 ()
22135

  • Electronystagmograph