The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D5L25
Not in Commercial Distribution

  • M272AU4D5L251 ()
  • 10381780036326 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
Not in Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L25
Not in Commercial Distribution

  • M272AU4D10L251 ()
  • 10381780036302 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
40M08
Not in Commercial Distribution

  • M27240M081 ()
  • 10381780034766 ()

  • Insertion needle 64mm Length


  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, MINI CONNECTOR
PMT CORPORATION
2101-06-MN-SS
In Commercial Distribution

  • 00650551041320 ()

  • Contact Length 5 Millimeter
  • Recording Depth 55 Millimeter
  • Spacing 10 Millimeter
  • Main Tube Length 32 Centimeter
2101-06-MN-SS

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-IL-SS
In Commercial Distribution

  • 00650551041313 ()

  • Main Tube Length 32 Centimeter
  • Spacing 10 Millimeter
  • Recording Depth 55 Millimeter
  • Contact Length 5 Millimeter
2101-06-IL-SS

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT (2MM), INLINE CONNECTOR
PMT CORPORATION
2101-06-121
In Commercial Distribution

  • 00650551041306 ()

  • Outer Diameter: 1.8 Millimeter
  • Spacing: 10 Millimeter
  • Recording Depth: 52 Millimeter
2101-06-121

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT (2MM), INLINE CONNECTOR
PMT CORPORATION
2101-06-120
In Commercial Distribution

  • 00650551041290 ()

  • Spacing: 5 Millimeter
  • Recording Depth: 27 Millimeter
  • Outer Diameter: 1.8 Millimeter
2101-06-120

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-099
In Commercial Distribution

  • 00650551041283 ()

  • Contact Length 5 Millimeter
  • Recording Depth 55 Millimeter
  • Spacing 10 Millimeter
  • Main Tube Length 32 Centimeter
2101-06-099

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-085
In Commercial Distribution

  • 00650551041276 ()

  • Recording Depth 52 Millimeter
  • Spacing 10 Millimeter
  • Main Tube Length 32 Centimeter
  • Contact Length 2 Millimeter
2101-06-085

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-072
In Commercial Distribution

  • 00650551041269 ()

  • Main Tube Length 32 Centimeter
  • Spacing 10 Millimeter
  • Recording Depth 55 Millimeter
  • Contact Length 5 Millimeter
2101-06-072

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-071
In Commercial Distribution

  • 00650551041252 ()

  • Main Tube Length 32 Centimeter
  • Spacing 11 Millimeter
  • Recording Depth 60 Millimeter
  • Contact Length 5 Millimeter
2101-06-071

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-051
In Commercial Distribution

  • 00650551041245 ()

  • Recording Depth 37 Millimeter
  • Spacing 7 Millimeter
  • Main Tube Length 32 Centimeter
  • Contact Length 2 Millimeter
2101-06-051

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-041
In Commercial Distribution

  • 00650551041238 ()

  • Contact Length 5 Millimeter
  • Recording Depth 55 Millimeter
  • Spacing 10 Millimeter
  • Main Tube Length 32 Centimeter
2101-06-041

  • Depth electrode
DEPTH ELECTRODE, STAINLESS STEEL, 6 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2101-06-039
In Commercial Distribution

  • 00650551041221 ()

  • Main Tube Length 32 Centimeter
  • Spacing 7.5 Millimeter
  • Recording Depth 42.5 Millimeter
  • Contact Length 5 Millimeter
2101-06-039

  • Depth electrode
DEPTH ELECTRODE, PLATINUM, 10 CONTACT, MINI CONNECTOR
PMT CORPORATION
2102-10-MN-SS
In Commercial Distribution

  • 00650551040859 ()

  • Recording Depth 47 Millimeter
  • Spacing 5 Millimeter
  • Main Tube Length 32 Centimeter
  • Contact Length 2 Millimeter
2102-10-MN-SS

  • Depth electrode
DEPTH ELECTRODE, PLATINUM, 10 CONTACT, INLINE CONNECTOR
PMT CORPORATION
2102-10-IL-SS
In Commercial Distribution

  • 00650551040842 ()

  • Contact Length 2 Millimeter
  • Main Tube Length 32 Centimeter
  • Spacing 5 Millimeter
  • Recording Depth 47 Millimeter
2102-10-IL-SS

  • Depth electrode
DEPTH ELECTRODE, PLATINUM, 10 CONTACT, MINI CONNECTOR
PMT CORPORATION
2102-10-087
In Commercial Distribution

  • 00650551040835 ()

  • Recording Depth 92 Millimeter
  • Spacing 10 Millimeter
  • Main Tube Length 32 Centimeter
  • Contact Length 2 Millimeter
2102-10-087

  • Depth electrode
< 1 ... 40 41 42 43 44 ... 71 >